CRANE, TX —
OSHA Inspection: TARGA MIDSTREAM SERVICES, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of TARGA MIDSTREAM SERVICES, LLC in 5601 FM 1053, CRANE, TX 79731 (NAICS 211112). OSHA activity number 343462156.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TARGA MIDSTREAM SERVICES, LLC
- Site address
- 5601 FM 1053
- City
- CRANE
- State
- TX
- ZIP
- 79731
- Mailing
- 5601 FM 1053, CRANE, TX 79731
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 211112
- Employees
- 25
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 II C
- Issued
- Jan 11, 2019
- Abate by
- Feb 7, 2019
- Penalty
- Initial $9,239 · Current $5,543 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(C): The energy control procedure did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them. On or about September 4, 2018 in the refrigeration compressors building the employer allowed employees to perform lock-out/tag-out work without specific energy control procedures while pulling a compressor piston on compressor #2.
Recent events (2)
- — I (S) $5543.4
- — Z (S) $9239
1910.147 D03
- Issued
- Jan 11, 2019
- Abate by
- Feb 7, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): On or about September 4, 2018 in the refrigeration compressors building the employer allowed employees to perform lock-out/tag-out work without first ensuring that all energy isolating devices were located and operated so to isolate Compressor #2 while performing routine maintenance.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D04 II
- Issued
- Jan 11, 2019
- Abate by
- Feb 7, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4)(ii): Lockout devices utilized were not affixed in a manner that held the energy isolating device in a safe or off position: On or about September 4, 2018 in the refrigeration compressors building the employer allowed employees to perform lock-out/tag-out work without first affixing lockout devices in a manner that held the energy isolating device in a safe position while performing routine maintenance on compressor #2.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 211112)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343462156.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.