Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TARGA MIDSTREAM SERVICES, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of TARGA MIDSTREAM SERVICES, LLC in 5601 FM 1053, CRANE, TX 79731 (NAICS 211112). OSHA activity number 343462156.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Targa Midstream Services, LLC — free Get an email when a new federal OSHA severe-injury report for Targa Midstream Services, LLC is published. One employer, no account, unsubscribe in one click.
Site address
5601 FM 1053
City
CRANE
State
TX
ZIP
79731
Mailing
5601 FM 1053, CRANE, TX 79731
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
211112
Employees
25
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 II C

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 11, 2019
Abate by
Feb 7, 2019
Penalty
Initial $9,239 · Current $5,543 Reduced
29 CFR 1910.147(c)(4)(ii)(C): The energy control procedure did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them.  On or about September 4, 2018 in the refrigeration compressors building the employer allowed employees to perform lock-out/tag-out work without specific energy control procedures while pulling a compressor piston on compressor #2.
Recent events (2)
  • — I (S) $5543.4
  • — Z (S) $9239

1910.147 D03

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 11, 2019
Abate by
Feb 7, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):  On or about September 4, 2018 in the refrigeration compressors building the employer allowed employees to perform lock-out/tag-out work without first ensuring that all energy isolating devices were located and operated so to isolate Compressor #2 while performing routine maintenance.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D04 II

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 11, 2019
Abate by
Feb 7, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(4)(ii): Lockout devices utilized were not affixed in a manner that held the energy isolating device in a safe or off position:  On or about September 4, 2018 in the refrigeration compressors building the employer allowed employees to perform lock-out/tag-out work without first affixing lockout devices in a manner that held the energy isolating device in a safe position while performing routine maintenance on compressor #2.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343462156.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.