HOUSTON, TX —
OSHA Inspection: J&M SALES OF TEXAS, LLC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of J&M SALES OF TEXAS, LLC. in 8201 BROADWAY STREET, HOUSTON, TX 77061 (NAICS 452112). OSHA activity number 343474060.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- J&M SALES OF TEXAS, LLC.
- Site address
- 8201 BROADWAY STREET
- City
- HOUSTON
- State
- TX
- ZIP
- 77061
- Mailing
- 8201 BROADWAY STREET, HOUSTON, TX 77061
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 452112
- Employees
- 14
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.37 A03
- Issued
- Dec 3, 2018
- Abate by
- Dec 7, 2018
- Penalty
- Initial $4,989 · Current $4,989
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: a) Near the employee break room, the fire exit was blocked by store merchandise and other items. b) In the stock room, the fire exit was locked by a cross bar.
Recent events (1)
- — Z (S) $4989
1910.303 G01 I A
- Issued
- Dec 3, 2018
- Abate by
- Dec 7, 2018
- Penalty
- Initial $4,989 · Current $4,989
General-duty citation text
29 CFR 1910.303(g)(1)(i)(A): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening whwere they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910: a) In the stock room, Panel HA 1 (480Y/277V 3ph 4W) was blocked. b) In the stock room, Panel HA 2 (480Y/277V 3ph 4W) was blocked.
Recent events (1)
- — Z (S) $4989
More inspections at J&M Sales of Texas, LLC.
View J&M Sales of Texas, LLC.'s full OSHA safety record →
More inspections in this industry (NAICS 452112)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343474060.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.