OSHA Inspection: BIO-DETEK, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of BIO-DETEK, INC. in 525 NARRAGANSETT PARK DRIVE, PAWTUCKET, RI 02861 (NAICS 339112). OSHA activity number 343481487.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bio-Detek, INC. — free Get an email when a new federal OSHA severe-injury report for Bio-Detek, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
BIO-DETEK, INC.
Site address
525 NARRAGANSETT PARK DRIVE
City
PAWTUCKET
State
RI
ZIP
02861
Mailing
525 NARRAGANSETT PARK DRIVE, PAWTUCKET, RI 02861
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339112
Employees
488
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 5, 2018
Abate by
Dec 23, 2018
Penalty
Initial $7,853 · Current $5,497 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:     (a) Worksite - Die Cutting Department:  On or about 9/21/2018, the employer had not developed machine specific lockout/tag-out procedures for the control of hazardous energy during servicing and maintenance activities.
Recent events (2)
  • — I (S) $5497
  • — Z (S) $7853

1910.147 C07 I B

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 5, 2018
Abate by
Oct 17, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure:   (a) Worksite - Die Cutting Department:  On or about 9/21/2018, the employer had not trained the machine operator in the purpose and use of the energy control procedure (Lockout/Tag-out), to include machine guarding applications.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343481487.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.