Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VIGLIOTTI BUILDERS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of VIGLIOTTI BUILDERS, INC. in 100 SOUTH SALINA STREET 2 CLINTON SQUARE, SYRACUSE, NY 13202 (NAICS 238320). OSHA activity number 343483442.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Vigliotti Builders, INC. — free Get an email when a new federal OSHA severe-injury report for Vigliotti Builders, INC. is published. One employer, no account, unsubscribe in one click.
Site address
100 SOUTH SALINA STREET 2 CLINTON SQUARE
City
SYRACUSE
State
NY
ZIP
13202
Mailing
3844 SPLIT ROCK ROAD, CAMILLUS, NY 13031
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238320
Employees
3
Ownership type
A

6 citations on file for this inspection.

1926.404 B01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 12, 2018
Abate by
Dec 24, 2018
Penalty
Initial $2,217 · Current $3,333
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection:    a) On or about 9/21/2018, in the atrium area:  A CAP C59960 paint sprayer was energized through an extension cord which was plugged into a floor outlet.  No GFCI protection was in use.     Abatement certification is required for this item.
Recent events (2)
  • — I (S) $3333.33
  • — Z (S) $2217

1926.451 E01

Serious Gravity 10 1 instance 2 exposed
Issued
Dec 12, 2018
Abate by
Dec 24, 2018
Penalty
Initial $3,880 · Current $3,333 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access:    a) On or about 9/21/2018, in the atrium area:  Safe means of egress was not provided to all levels of the scaffold being used by employees who were painting.  A built in ladder between two working levels of supported scaffolding did not extend to the upper level, was over 1.5 feet horizontally from the upper level, and there was no opening in the rail system.  Employees were traversing between levels by climbing exterior bracing.  Employees were exposed to falls of over 29 feet.    Abatement documentation is required for this item.
Recent events (2)
  • — I (S) $3333.33
  • — Z (S) $3880

1926.501 B01

Serious Gravity 10 3 instances 3 exposed
Issued
Dec 12, 2018
Abate by
Dec 24, 2018
Penalty
Initial $3,880 · Current $0 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:    a) On or about 9/21/2018, in the atrium area:  Employees walking and working on the first floor center crossover were exposed to two 68 inch wide unguarded wall openings located on the North side of the crossover.  Employees exposed to falls of approximately 17 feet.      b) On or about 9/21/2018, in the atrium area:  Employees walking and working on the second floor, West side, were exposed to unguarded floor openings.   Employees were exposed to falls to the first floor elevation and to the basement elevation.  Employees were exposed to falls of up to 32 feet.      c) On or about 9/21/2018, in the atrium area:  Employees walking and working on the second floor at the North West corner material staging area were exposed to falls of 32 feet to the basement.         Abatement documentation is required for these items.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3880

1926.451 F03

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 12, 2018
Abate by
Dec 24, 2018
Penalty
Initial $2,772 · Current $3,333
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity:    a) On or about 9/21/2018, in the atrium area:  Supported scaffolding being utilized by employees who were painting was not inspected prior to use on a daily basis by a competent person.       Abatement certification is required for this item.
Recent events (2)
  • — I (S) $3333.33
  • — Z (S) $2772

1926.454 A

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 12, 2018
Abate by
Jan 9, 2019
Penalty
Initial $2,772 · Current $0 Reduced
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards:    a) On or about 9/21/2018, in the atrium area:  Employees working from supported scaffolding were not provided with training regarding the recognition and avoidance of hazards associated with scaffold use.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2772

1926.503 A02

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 12, 2018
Abate by
Jan 9, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(2): At this job site, the employer had not assured that each employee has been trained, as necessary, by a competent person qualified in fall hazards:    a) On or about 9/21/2018, in the atrium area:  Employees were exposed to various fall hazards.  Employees had not been provided with any training regarding the recognition and avoidance of fall hazards, along with the proper use of fall protection.    Abatement certification Is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Vigliotti Builders, INC.'s full OSHA safety record →