Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BREVARD SOFFIT & SIDING INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of BREVARD SOFFIT & SIDING INC in 1473 PALEY CIR. S.E., PALM BAY, FL 32909 (NAICS 238390). OSHA activity number 343483921.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Brevard Soffit & Siding INC — free Get an email when a new federal OSHA severe-injury report for Brevard Soffit & Siding INC is published. One employer, no account, unsubscribe in one click.
Site address
1473 PALEY CIR. S.E.
City
PALM BAY
State
FL
ZIP
32909
Mailing
2560 BILLIE LANE, MALABAR, FL 32950
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238390
Employees
20
Ownership type
A

2 citations on file for this inspection.

1926.416 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 18, 2018
Abate by
Dec 31, 2018
Penalty
Initial $4,656 · Current $2,794 Reduced
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:  a) On or about 9/11/2018, on the south side of the house located at 1473 Paley Cir. S.E.  Palm Bay, FL, an employee was exposed to an electrocution hazard while carrying a J Channel of approximately 12 feet long  while climbing up an extension ladder. The piece of J channel contacted a 13.2kV phase to ground overhead power line.
Recent events (2)
  • — I (S) $2793.6
  • — Z (S) $4656

1926.416 A03

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 18, 2018
Abate by
Dec 31, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.416(a)(3): Before work began, the employer did not ascertain by inquiry, direct observation, or by instruments, whether any part of an energized electric power circuit, exposed or concealed, was so located that the performance of the work could bring any person, tool, or machine into pysical or electrical contact with the electric power circuit.  a) On or about 9/11/2018, on the south side of the house located at 1473 Paley Cir. S.E.  Palm Bay, FL, an employee was exposed to an electrical shock hazard while carrying a J Channel of approximately 12 feet long while on an extension ladder. The piece of J channel contacted a 13.2kV phase to ground overhead power line.