Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: J ROCK EXTERIORS INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of J ROCK EXTERIORS INC. in 920 S MILITARY RD, FOND DU LAC, WI 54935 (NAICS 238160). OSHA activity number 343488490.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch J Rock Exteriors INC. — free Get an email when a new federal OSHA severe-injury report for J Rock Exteriors INC. is published. One employer, no account, unsubscribe in one click.
Site address
920 S MILITARY RD
City
FOND DU LAC
State
WI
ZIP
54935
Mailing
814 E OLDE WILLOW #216, PROSPECT HEIGHTS, IL 60070
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
9
Ownership type
A

4 citations on file for this inspection.

1926.501 B13

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 11, 2019
Penalty
Initial $2,356 · Current $1,649 Reduced
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure.  On or about September 25, 2018 employees installing shingles on a 6:12 to 12:12 pitch three story building were not protected from the 27+ ft. fall hazard due to an incomplete fall protection system being utilized.
Recent events (2)
  • — I (S) $1649.2
  • — Z (S) $2356

1926.503 B01

Other-than-serious 9 instances 9 exposed
Issued
Jan 11, 2019
Abate by
Jan 25, 2019
Penalty
Initial $264 · Current $185 Reduced
29 CFR 1926.503(b)(1): The employer shall verify compliance with paragraph (a) of this section by preparing a written certification record. The written certification record shall contain the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. If the employer relies on training conducted by another employer or completed prior to the effective date of this section, the certification record shall indicate the date the employer determined the prior training was adequate rather than the date of actual training:   On or about September 25, 2019 the employer did not provide written certification that each employee working on an elevated surface had been trained in the recognition and utilization of fall protection systems.
Recent events (2)
  • — I (O) $184.8
  • — Z (O) $264

1926.1053 B01

Other-than-serious 1 instance 9 exposed
Issued
Jan 11, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grab-rail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support:     On or about September 25, 2018 the portable extension ladder used to access the dormer and/or first story roof did not extend three feet beyond the upper landing surface.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.1053 B05 I

Other-than-serious 1 instance 9 exposed
Issued
Jan 11, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladders shall be used at an angle such that the horizontal distance from the top support to the foot of the ladder is approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support):  On or about September 25, 2018 the non-self-supporting ladder used by employees to access the first story flat roof was not positioned to meet the standard requirements; it was set at a 1:1 ratio, instead for the required 4:1 ratio.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343488490.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.