Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CLARUS FLUID INTELLIGENCE LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CLARUS FLUID INTELLIGENCE LLC in 7421 CENTRAL BUSINESS PARK DR., STE 107B, NORFOLK, VA 23513 (NAICS 336611). OSHA activity number 343490512.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Clarus Fluid Intelligence LLC — free Get an email when a new federal OSHA severe-injury report for Clarus Fluid Intelligence LLC is published. One employer, no account, unsubscribe in one click.
Site address
7421 CENTRAL BUSINESS PARK DR., STE 107B
City
NORFOLK
State
VA
ZIP
23513
Mailing
7421 CENTRAL BUSINESS PARK DR., STE 107B, NORFOLK, VA 23513
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336611
Employees
11
Ownership type
A

8 citations on file for this inspection.

1910.28 B01 I

Other-than-serious 1 instance 2 exposed
Issued
Nov 7, 2018
Abate by
Dec 5, 2018
Penalty
Initial $5,497 · Current $3,460 Reduced
29 CFR 1910.28(b)(1)(i): Except as provided elsewhere in this section, the employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following: guardrail systems, safety net systems, or personal fall protection systems, such as a personal fall arrest, travel restraint, or positioning system:  a) 7421 Central Business Park Dr., Ste 107B, Norfolk, VA 23513, outside warehouse/shop: On or about September 26, 2018, and times prior thereto, the employer did not ensure each employee was protected from falls to a lower level during cleaning of 4,000-gallon tanks and confined space hole watch activities, with an approximately 9'1" fall distance to ground, exposing employees to fall hazards.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $3460
  • — Z (S) $5497

1910.110 F02 I

Serious Gravity 1 1 instance 11 exposed
Issued
Nov 7, 2018
Abate by
Dec 5, 2018
Penalty
Initial $3,298 · Current $2,080 Reduced
29 CFR 1910.110(f)(2)(i): LP gas container(s) in storage were not located so as to minimize exposure to excessive temperature rise, physical damage, or tampering by unauthorized persons:  a) 7421 Central Business Park Dr., Ste 107B, Norfolk, VA 23513, warehouse/shop: On or about September 26, 2018, and times prior thereto, an approximately 100-pound propane cylinder in storage was not protected from forklift traffic or tampering, exposing employees to potential for collision and other hazards.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $2080
  • — Z (S) $3298

1910.110 F02 II

Serious Gravity 1 1 instance 11 exposed
Issued
Nov 7, 2018
Abate by
Dec 5, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.110(f)(2)(ii): LP gas container(s) stored inside were located near or in area(s) normally used or intended for the safe exit of employees:  a) 7421 Central Business Park Dr., Ste 107B, Norfolk, VA 23513, warehouse/shop: On or about September 26, 2018, and times prior thereto, a 20-pound propane tank was located in an exit route, exposing employees to potential fire and other hazards.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 B02 IV

Other-than-serious 1 instance 11 exposed
Issued
Nov 7, 2018
Abate by
Dec 5, 2018
Penalty
Initial $5,497 · Current $3,465 Reduced
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use:  a) 7421 Central Business Park Dr., Ste 107B, Norfolk, VA 23513, warehouse/shop: On or about September 26, 2018, and times prior thereto, a 367 cubic foot acetylene fuel cylinder did not have a valve protection cap in place, where the gas cylinder was stored and not connected for use, exposing employees to potential fire and explosion hazards.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $3465
  • — Z (S) $5497

1910.303 B02

Other-than-serious 1 instance 1 exposed
Issued
Nov 7, 2018
Abate by
Dec 5, 2018
Penalty
Initial $4,398 · Current $2,770 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a) 7421 Central Business Park Dr., Ste 107B, Norfolk, VA 23513, outside warehouse/shop: On or about September 26, 2018, and times prior thereto, an extension cord was used to supply power to a second extension cord and a portable Skil 9216 reciprocating saw, exposing employees to potential fire hazards.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $2770
  • — Z (S) $4398

1910.304 G05

Other-than-serious 1 instance 1 exposed
Issued
Nov 7, 2018
Abate by
Dec 5, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:  a) 7421 Central Business Park Dr., Ste 107B, Norfolk, VA 23513, outside warehouse/shop: On or about September 26, 2018, and times prior thereto, an extension cord used to supply power to portable tools such as, but not limited to, a Skil 9216 reciprocating saw did not maintain a continuous path to ground, exposing employees to potential shock hazards.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.305 A02 X

Other-than-serious 1 instance 1 exposed
Issued
Nov 7, 2018
Abate by
Dec 5, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(a)(2)(x): Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points:  a) 7421 Central Business Park Dr., Ste 107B, Norfolk, VA 23513, warehouse/shop: On or about September 26, 2018, and times prior thereto, an extension cord used to supply power to a second extension cord was run through a doorway to access an outlet inside the building, and was not protected from being pinched under the door, exposing employees to shock hazards.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.334 A02 II

Other-than-serious 1 instance 1 exposed
Issued
Nov 7, 2018
Abate by
Dec 5, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service:  a) 7421 Central Business Park Dr., Ste 107B, Norfolk, VA 23513, outside warehouse/shop: On or about September 26, 2018, and times prior thereto, an extension cord used to supply power to portable tools such as, but not limited to, a Skil 9216 reciprocating saw, had outer sheathing that was pulled away from the receptacle end, exposing employees to potential shock hazards.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343490512.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.