Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: EIGHT BROTHERS DEVELOPMENT LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of EIGHT BROTHERS DEVELOPMENT LLC in 3800 NEW HAMPSHIRE AVE NW, WASHINGTON, DC 20008 (NAICS 238350). OSHA activity number 343492609.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Eight Brothers Development LLC — free Get an email when a new federal OSHA severe-injury report for Eight Brothers Development LLC is published. One employer, no account, unsubscribe in one click.
Site address
3800 NEW HAMPSHIRE AVE NW
City
WASHINGTON
State
DC
ZIP
20008
Mailing
2138 WISCONSIN AVE NW, WASHINGTON, DC 20007
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238350
Employees
6
Ownership type
A

3 citations on file for this inspection.

1926.451 E09 I

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 11, 2019
Abate by
Feb 15, 2019
Penalty
Initial $3,580 · Current $3,580
29 CFR 1926.451(e)(9)(i): The employer did not provide safe means of access for each employee erecting or dismantling a scaffold:  a) Front of Structure, Right Side - Workers assembling a tubular welded frame scaffold were climbing the scaffolding frames to access the highest platform level, approximately 26 feet above ground, on or about, 9/26/2018.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $3580

1926.451 G02

Serious Gravity 10 2 instances 2 exposed
Issued
Feb 11, 2019
Abate by
Feb 15, 2019
Penalty
Initial $3,580 · Current $3,580
29 CFR 1926.451(g)(2): The employer did not provide fall protection for employees erecting or dismantling supported scaffolds:  a) Front Center, Top Level of Scaffolding - A worker on an unguarded platform was assembling a tubular welded frame scaffolding system without fall protection, exposed to a 26 foot fall hazard, on or about 9/26/2018.     b) Front Right Side, Top Level of Scaffolding - A worker was moving between the scaffolding system on an unguarded platform without fall protection, exposed to a 26 foot fall hazard, on or about 9/26/2018.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $3580

1926.454 B01

Serious Gravity 10 1 instance 3 exposed
Issued
Feb 11, 2019
Abate by
Feb 15, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.454(b)(1): The employer did not have each employee who is involved in erecting, disassembling, moving, operating, maintaining, or inspecting a scaffold trained by a competent person to recognize the hazards associated with the work in question.  Job Site - Company owner could not provide information regarding who provided training, when or where  training was conducted, on or about 9/26/2018.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $0

View Eight Brothers Development LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343492609.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.