Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PIEDMONT WOODS PRODUCTS, LLC

Monitoring inspection · Safety discipline

On , OSHA opened a monitoring safety inspection of PIEDMONT WOODS PRODUCTS, LLC in 101 FOLENDORE RD, GRAY, GA 31032 (NAICS 321113). OSHA activity number 343492906.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Piedmont Woods Products, LLC — free Get an email when a new federal OSHA severe-injury report for Piedmont Woods Products, LLC is published. One employer, no account, unsubscribe in one click.
Site address
101 FOLENDORE RD
City
GRAY
State
GA
ZIP
31032
Mailing
P.O. BOX 123, BOLINGBROKE, GA 31004
Inspection type
Monitoring (D)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321113
Employees
8
Ownership type
A

20 citations on file for this inspection.

1910.36 D01

Serious Gravity 5 1 instance 8 exposed
Issued
Mar 14, 2019
Abate by
Apr 9, 2019
Penalty
Initial $3,126 · Current $700 Reduced
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge:    a) Throughout the facility: On or about September 27, 2018, and at times prior to, the employer did not ensure that emergency exit doors could be open without special tools or knowledge when an exit door was lock with a screw that required more than one operation to remove.  In case of fire or other emergency requiring evacuation, employees were exposed to entrapment, burns, and smoke inhalation hazards.
Recent events (3)
  • — F (S) $700
  • — C (S) $3126
  • — Z (S) $3126

1910.37 B01

Serious Gravity 5 1 instance 8 exposed
Issued
Mar 14, 2019
Abate by
Apr 9, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(1): Each exit route was not adequately lighted so that an employee with normal vision can see along the exit route.  a) Exit next to the extractor: On or about September 27,  2018, and at times prior to, the employer did not ensure that that exit doors lighting was installed when the exit door did not have emergency lighting installed.  In case of fire or other emergency requiring evacuation, employees were exposed to entrapment, burns, and smoke inhalation hazards.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.101 B

Serious Gravity 5 1 instance 8 exposed
Issued
Mar 14, 2019
Abate by
Apr 9, 2019
Penalty
Initial $2,500 · Current $700 Reduced
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6: (3.3.8 - Where caps were provided for valve protection, such caps were not kept on cylinders in storage)    On or about September 2018, and at times prior to, employees were exposed to struck-by hazards where compressed gas cylinders were stored without their valve caps.  Instances include, but are not limited to the following:    a) Storage inside next to lunch table:  A cylinder containing Compressed Gas, N.O.S. (Argon 75%, Carbon Dioxide 25%).    b) Storage inside next to break/lunch area: At least two (2) compressed gas cylinders containing oxygen were stored without valve caps. Employees were exposed to struck-by hazards when compressed gas cylinders used for oxy-fuel gas welding were stored without valve caps.
Recent events (3)
  • — F (S) $700
  • — C (S) $2500
  • — Z (S) $2500

1910.147 C04 II

Serious Gravity 10 4 instances 8 exposed
Issued
Mar 14, 2019
Abate by
Apr 9, 2019
Penalty
Initial $4,376 · Current $700 Reduced
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):     On or about Septmeber 27, 2018, and at times prior to, employees perform maintenance and servicing on various equipment.  Employees were exposed to struck by, caught in and amputation hazards when the specific procedures did not contain enough specificity.  Deficiencies included but were not limited to the following:     a) RESAW - Procedures did not include the purposed and/or scope.   b) GANG SAW - Procedures did not include the purposed and/or scope.   c) CHOP SAW -  Procedures did not include the purposed and/or scope.   d) BLOWER -  Procedures did not include the purposed and/or scope.
Recent events (3)
  • — F (S) $700
  • — C (S) $4376
  • — Z (S) $4376

1910.147 C04 II B

Serious Gravity 10 4 instances 8 exposed
Issued
Mar 14, 2019
Abate by
Apr 9, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedure did not clearly and specifically specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy:  On or about September 27, 2018 , and at times prior to, employees perform maintenance and servicing on various equipment.  Employees were exposed to struck by, caught in and amputation hazards when the specific procedures did not contain enough specificity.  Deficiencies included but were not limited to the following:    a) RESAW - The procedure states,  "switching off the machine at the breaker panel", but it does specify which breaker is needed to shut off the equipment.  b) GANG SAW - The procedure states, "the breaker on the electrical panel is to be switched OFF and locked out.", but does not indicate which breaker to shut off.  c) CHOP SAW -  The procedure states "the breaker on the electrical panel is to be switched OFF and locked out", but does specify which breaker to shut off  d) BLOWER -  The procedure states, " the breaker on the electrical panel is to be switched OFF and locked out", but does not specify which breaker to shut off. e) Gang Saw- The procedures states, "The infeed and outfeed conveyors are controlled by the hydraulic system", but does not indicate how to lock out the hydraulics.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.147 C04 II D

Serious Gravity 10 5 instances 8 exposed
Issued
Mar 14, 2019
Abate by
Apr 9, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control  On or about September 27, 2018, and at times prior to, employees perform maintenance and servicing on various equipment.  Employees were exposed to struck by, caught in and amputation hazards when the specific procedures did not contain enough specificity.  Deficiencies included but were not limited to the following:    a) RESAW - The procedure does not indicate how to verify that the electrical energy has been lock out.    b) GANG SAW - The procedure does not indicate how to verify that the electrical energy has been lock out.     c) CHOP SAW -  The procedure does not indicate how to verify that the electrical energy has been lock out.    d) BLOWER -  The procedure does not indicate how to verify that the electrical energy has been lock out.    e) Gang Saw- The procedure does not indicate how to verify that the hydraulics has been lock out.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.157 C01

Serious Gravity 10 4 instances 8 exposed
Issued
Mar 14, 2019
Abate by
Apr 9, 2019
Penalty
Initial $4,376 · Current $700 Reduced
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:    On or about September 27, 2018, and at times prior to, employees to hazards associated with improperly stored fire extinguishers where the following deficiencies found included, but were not limited to:    a)  Entry door machine shop,: A portable fire extinguisher was located on top of a table, was not mounted or its location identified and it was tag properly.    b)  Machine Line: The fire extinguisher was mounted, but its location was not identified, it was partially blocked by wood products and it was not charged.    c)  Key Stone Machine: A fire extinguisher was placed on top machinery, not mounted and not charged nor inspected since 2008.      d) Office area: A fire extinguisher was mounted not identified nor did it have the yellow inspection tag attached, but it was charged.
Recent events (3)
  • — F (S) $700
  • — C (S) $4376
  • — Z (S) $4376

1910.157 C04

Serious Gravity 5 2 instances 8 exposed
Issued
Mar 14, 2019
Abate by
Apr 9, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(4): Portable fire extinguishers were not maintained in a fully charged and operable condition:  On or about September 27, 2018 and at times prior to, the employer did not ensure that fire extinguishers were fully charged and in an operable condition.  a)    Machine Line: The fire extinguisher available for use at the machine line where the product is trim, cut and made was not charged.  The gauge was showing zero pressure.  b)    Key Stone Machine: The fire extinguisher available for use at the machine line where the product is trim, cut and made was not charged.  The gauge was showing zero pressure. The tag indicated that it was inspected since 2008.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.157 E02

Serious Gravity 5 4 instances 8 exposed
Issued
Mar 14, 2019
Abate by
Apr 9, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:  On or about September 27, 2018 and at times prior to throughout the facility, employees engaged in work activities associated with the production of wood products were exposed to hazards associated with portable fire extinguishers that were not inspected on a monthly basis.  Deficiencies noted included, but were not limited to fire extinguishers not mounted or located in designated areas, blocked by equipment, not fully charged, and missing annual inspection tags.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.157 E03

Serious Gravity 5 2 instances 8 exposed
Issued
Mar 14, 2019
Abate by
Apr 9, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(3): The date of the annual maintenance check of portable fire extinguishers was not recorded:  a) On or about September 2018,  and at times prior to, the employer did not ensure that the date of annual maintenance was recorded, when a fire extinguisher did not have the yellow maintenance record attached.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.157 G01

Serious Gravity 5 1 instance 8 exposed
Issued
Mar 14, 2019
Abate by
Apr 9, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting:  a) Throughout the facility - On or about September 27, 2018, and at times prior to, the employer did not train employees who were expected to use the fire extinguishers in case of a fire. Employees were exposed to fire hazards.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.178 A04

Serious Gravity 10 1 instance 3 exposed
Issued
Mar 14, 2019
Abate by
Apr 9, 2019
Penalty
Initial $4,376 · Current $700 Reduced
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval:    Throughout the facility: On or about October 10, 2018, and at times prior to, employees used Mitsubishi sit down forklift  Model FGC30K, SN: AF83E00080 with a personnel platform to lift employees to perform maintenance tasks.  Employees were exposed to falling from distances up to 6-feet to the concrete below. The manufacturer did not approve the use of the platform.
Recent events (3)
  • — F (S) $700
  • — C (S) $4376
  • — Z (S) $4376

1910.212 A01

Serious Gravity 10 2 instances 7 exposed
Issued
Mar 14, 2019
Abate by
Apr 9, 2019
Penalty
Initial $4,376 · Current $700 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    a) Resaw : On our about September 27, 2018 and at times prior to, employees were exposed to caught in between hazards when the saw was not guarded when employees including, but not limited to feed the wood and walking the area.      b) Key stone: On our about September 27, 2018 and at times prior to, employees were exposed to caught in between hazards when a rotating circular shaft was not guarded when employees including, but not limited to feed the wood and walking the area.    c) Quality Machinery: On our about September 27, 2018 and at times prior to, employees were exposed to caught in between hazards when rotating rollers where not guarded for employees including, but not limited to feeding, walking and picking up the wood on the opposite side.
Recent events (3)
  • — F (S) $700
  • — C (S) $4376
  • — Z (S) $4376

1910.219 D01

Serious Gravity 10 1 instance 8 exposed
Issued
Mar 14, 2019
Abate by
Apr 9, 2019
Penalty
Initial $4,376 · Current $700 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    On or about September 27, 2018, and at times prior to,       a)  Smith Band SAW:  The employer did not ensure the pulleys of the machine were guarded.  The operators including, but not limited to, walking the area, feed and picking up plywood, exposing the employee to amputations and caught in between hazards.
Recent events (3)
  • — F (S) $700
  • — C (S) $4376
  • — Z (S) $4376

1910.219 F03

Serious Gravity 10 2 instances 8 exposed
Issued
Mar 14, 2019
Abate by
Apr 9, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven 7 feet or less above floors or platforms were not enclosed:  a) Smith Band Saw: On or about September 27, 2018, and at times prior to, the employer did not ensure that the nip point on a traversing motion sprocket and chain system were guarded where plywood was being placed and stacked.  Employees at the Band Saw were exposed to amputations and caught in between hazards.  b) Chop Saw: On or about September 27, 2018, and at times prior to, the employer did not ensure that the nip point on a traversing motion sprocket and chain system were guarded where plywood was being cut and placed into a conveyor.  Employees at the Band Saw were exposed to amputations and caught in between hazards.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.303 F02

Serious Gravity 10 2 instances 8 exposed
Issued
Mar 14, 2019
Abate by
Apr 9, 2019
Penalty
Initial $4,376 · Current $700 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:     a) Breaker # 1 main breaker box on production floor:  On or about September 27, 2018, and at times prior to employees were engaged in work activities including but not limited maintenance and operation of machines receiving power from a panel box controlling equipment such as but not limited to the Band Saw, Blower, Shop Saw, Resaw and Key Stone Machine.  The panel box had some breakers labeled, but other breakers were not labeled or the handwriting was illegible.    b) Breaker # 2, next to the office:  On or about November 7, 2017, and at times prior to employees were engaged in work activities including but not limited maintenance and operation of machines receiving power from a panel box controlling equipment such as but not limited to the light fixtures and outlet that power the fans. The panel box had none of the breakers were labeled.
Recent events (3)
  • — F (S) $700
  • — C (S) $4376
  • — Z (S) $4376

1910.303 G02 I

Serious Gravity 5 3 instances 8 exposed
Issued
Mar 14, 2019
Abate by
Apr 9, 2019
Penalty
Initial $3,751 · Current $700 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    a)  Extension cable outside lunch table: On or about September 27, 2018 , and at times prior to, employees were exposed to electric shock hazards where an extension cord connected to a Mobil home had exposed cooper and it was lived exposing employees walking the area to electric shock hazards.    b) Extension cable production line: On or about September 27, 2018 , and at times prior to, employees were exposed to electric shock hazards where an extension cord connected to not limited to fans had exposed wires and it was lived exposing employees walking the area to electric shock hazards.
Recent events (3)
  • — F (S) $700
  • — C (S) $3751
  • — Z (S) $3751

1910.305 G02 III

Serious Gravity 5 1 instance 8 exposed
Issued
Mar 14, 2019
Abate by
Apr 9, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  a) production line: On or about September 27, 2018, and at times prior to, employees were exposed to electroshocked hazards when extensions cords were connected without strain relief and attached to the ceiling and running across the building platform.  The extension cord was used to provide power equipment including but not limited to, phones and other equipment used throughout the day.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.305 G01 IV D

Serious Gravity 1 1 instance 5 exposed
Issued
Mar 14, 2019
Abate by
Apr 9, 2019
Penalty
Initial $1,875 · Current $700 Reduced
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords and cables were attached to building surfaces:     Production line: On or about September 27, 2018, and at times prior to, employees were exposed to hazards associated with the use of extension cords attached to the ceiling and running across the building platform.  The extension cord was used to provide power equipment including but not limited to, phones and other equipment used throughout the day.
Recent events (3)
  • — F (S) $700
  • — C (S) $1875
  • — Z (S) $1875

1910.22 A01

Repeat Gravity 5 1 instance 8 exposed
Issued
Mar 14, 2019
Abate by
Apr 9, 2019
Penalty
Initial $6,252 · Current $1,000 Reduced
29 CFR 1910.22(a)(1): (1) All places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition.    On or about September 27, 2019 and at times prior to, the employer did not ensure that all work areas were keep clean and orderly when including, but not limited to piles of saw dust where left on the floor, walking working surfaces where cover with a dark liquid. Exposing employees to slip hazards.    The Piedmont Woods Products, LLC. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.22(a)(1), which was contained in OSHA inspection number 1147325, citation number 1, item number 1 and was affirmed as a final order on (date), with respect to a workplace located at101 Folendore Rd  Gray, GA 31032.
Recent events (3)
  • — F (R) $1000
  • — C (R) $6252
  • — Z (R) $6252

View Piedmont Woods Products, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343492906.