WASHINGTON, DC —
OSHA Inspection: CUSTOM CARPENTRY CONSTRUCTION INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CUSTOM CARPENTRY CONSTRUCTION INC. in 3156 MONROE STREET NE, WASHINGTON, DC 20018 (NAICS 238130). OSHA activity number 343496691.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CUSTOM CARPENTRY CONSTRUCTION INC.
- Site address
- 3156 MONROE STREET NE
- City
- WASHINGTON
- State
- DC
- ZIP
- 20018
- Mailing
- 10074 COLONIAL DRIVE, ELLICOTT CITY, MD 21042
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 5
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.501 B13
- Issued
- Jan 30, 2019
- Abate by
- Feb 5, 2019
- Penalty
- Initial $3,978 · Current $2,050 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Roof Frame, Right Side Front to Back - Four workers securing roof trusses to the structure were exposed to a 10 foot fall to the inside and a 25 foot fall to the outside of the structure due to a lack of fall protection, on or about 9/27/2018. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $2050
- — Z (S) $3978
1926.503 B01
- Issued
- Jan 30, 2019
- Abate by
- Feb 5, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section (fall protection training) by preparing a written certification record which contained the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer: (a) Job Site - Four workers were securing roof trusses to the structure not protected from falling, the employer did not prepare a written certification verifying that employees had been trained in hazards related to falls from elevation, on or about 9/27/2018. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B01
- Issued
- Jan 30, 2019
- Abate by
- Feb 5, 2019
- Penalty
- Initial $2,842 · Current $2,050 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) Front Right Side, Ground to Second Level Window Opening - The ladder used by the workers to gain access to the upper level extended approximately 12 inches above opening on or about 9/27/2018. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet)
Recent events (2)
- — I (S) $2050
- — Z (S) $2842
1926.1060 A
- Issued
- Jan 30, 2019
- Abate by
- Feb 5, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would train each employee in the procedures to be followed to minimize hazards related to ladders and stairways: Job site, front right side, aluminum extension ladder used to gain access to the second level and wooden job site ladder used to gain access to the first level, on or about 9/27/2018. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Custom Carpentry Construction INC.
View Custom Carpentry Construction INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343496691.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.