SAN ANTONIO, TX —
OSHA Inspection: ADVANCED TECHNOLOGY RECYCLING
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of ADVANCED TECHNOLOGY RECYCLING in 8559 NE INTERSTATE 410 LOOP STE B-144, SAN ANTONIO, TX 78219 (NAICS 562920). OSHA activity number 343504965.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ADVANCED TECHNOLOGY RECYCLING
- Site address
- 8559 NE INTERSTATE 410 LOOP STE B-144
- City
- SAN ANTONIO
- State
- TX
- ZIP
- 78219
- Mailing
- PO 75, PONTIAC, IL 61764
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 562920
- Employees
- 70
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.178 P01
- Issued
- Jan 24, 2019
- Abate by
- Feb 4, 2019
- Penalty
- Initial $5,304 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s): Warehouse: On or about October 2, 2018, and at times prior thereto, employees were exposed to struck-by hazards while operating a Mitsubishi forklift, which had a defective emergency brake.
Recent events (2)
- — I (S) $2500
- — Z (S) $5304
1910.303 B02
- Issued
- Jan 24, 2019
- Abate by
- Feb 4, 2019
- Penalty
- Initial $3,978 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: Warehouse, Demanufacturing Area: On or about October 2, 2018, and at times prior thereto, employees were exposed to electrical hazards, while using a relocatable power tap outside its UL listing to power equipment such as, but not limited to, drill charging stations, fans, and extension cords.
Recent events (2)
- — I (S) $1500
- — Z (S) $3978
1910.305 G01 IV D
- Issued
- Jan 24, 2019
- Abate by
- Feb 4, 2019
- Penalty
- Initial $3,978 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords and cables were attached to building surfaces: Warehouse, Demanufacturing Area: On or about October 2, 2018, and at times prior thereto, employees were exposed to electrical hazards, while using an extension cord that was ran from the ceiling above as a power source for equipment such as, but not limited to, drill charging stations, fans, and relocatable power taps.
Recent events (2)
- — I (S) $0
- — Z (S) $3978
More inspections at Advanced Technology Recycling
View Advanced Technology Recycling's full OSHA safety record →
More inspections in this industry (NAICS 562920)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343504965.