Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GEORGE'S RENOVATIONS, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GEORGE'S RENOVATIONS, LLC in 155 BROOKDALE DR, SPRINGFIELD, MA 01108 (NAICS 238170). OSHA activity number 343512307.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch George'S Renovations, LLC — free Get an email when a new federal OSHA severe-injury report for George'S Renovations, LLC is published. One employer, no account, unsubscribe in one click.
Site address
155 BROOKDALE DR
City
SPRINGFIELD
State
MA
ZIP
01108
Mailing
1680 RIVERDALE ST #C, WEST SPRINGFIELD, MA 01089
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
8
Ownership type
A

4 citations on file for this inspection.

1926.403 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 12, 2018
Penalty
Initial $2,439 · Current $1,220 Reduced
29 CFR 1926.403(b)(2):  Listed, labeled, and/or certified equipment was not installed and/or used in accordance with instructions included in the listing, labeling, and/or certification:  a) 155 Brookdale Dr., Springfield, MA: On or about October 3, 2018, an employee was observed operating a Milwaukee brand paddle mixer powered through extension cords that were plugged together in parallel  (daisy chained) to extend their reach.
Recent events (2)
  • — I (S) $1219.5
  • — Z (S) $2439

1926.404 F06

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 12, 2018
Abate by
Dec 24, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(6):  The path to ground from circuits, equipment, and enclosures was not permanent and continuous:  a) 155 Brookdale Dr., Springfield, MA: On or about October 3, 2018, an employee was observed using an extension cord that had no grounding pin as part of a set of extension cords strung together, some of which had grounding pins.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.405 G02 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 12, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(2)(iv):  Flexible cords were not connected to devices and fittings so that strain relief was provided which will prevent pull from being directly transmitted to joints or terminal screws:  a) 155 Brookdale Dr., Springfield, MA: On or about October 3, 2018, an extension cord was observed in use that had no strain relief as the plug was pulled away from the conductors.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

5(a)(1)

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 12, 2018
Penalty
Initial $4,268 · Current $2,134 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that an employee was exposed to a fall hazard:  a) 155 Brookdale Dr., Springfield, MA: On or about October 3, 2018, an employee was observed working from a raised aerial lift (Genie S -45)  with his Guardian brand lifeline/lanyard tied to itself around the rails of the aerial lift. Among other methods, feasible and acceptable means to correct this hazard is: 1. Ensure that employees are trained and follow the manufacturer's recommendation printed on the lift which state "attach lanyard to anchor provided in platform" 2. Ensure that employees are trained and follow the manufacturers (Guardian VLA-50) recommendation that, "if the shock absorber is built into the leg of the rope grab, positioning device or fall arrester, that portion must be attached to the user's approved body harness".
Recent events (2)
  • — I (S) $2134
  • — Z (S) $4268

View George'S Renovations, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343512307.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.