SKOKIE, IL —
OSHA Inspection: O. C. KECKLEY COMPANY
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of O. C. KECKLEY COMPANY in 3400 CLEVELAND STREET, SKOKIE, IL 60076 (NAICS 332911). OSHA activity number 343512315.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- O. C. KECKLEY COMPANY
- Site address
- 3400 CLEVELAND STREET
- City
- SKOKIE
- State
- IL
- ZIP
- 60076
- Mailing
- 3400 CLEVELAND STREET, SKOKIE, IL 60076
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332911
- Employees
- 35
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.147 C01
- Issued
- Dec 4, 2018
- Abate by
- Dec 31, 2018
- Penalty
- Initial $5,174 · Current $2,483 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: (a)Facility Wide - On October 4, 2018, the employer did not develop, document and utilize an energy control procedure (lockout/tagout program) and did not provide training on the energy control procedure to ensure that all required elements of the procedure were understood by employees and that the knowledge and skills required for the safe application, usage and removal of the energy controls were acquired by employees performing servicing or maintenance on a machine or an equipment such as wheel changes on the grinders and set-up on CNC machines. In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete and must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase, or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $2483
- — Z (S) $5174
1910.178 L01 I
- Issued
- Dec 4, 2018
- Abate by
- Dec 21, 2018
- Penalty
- Initial $7,760 · Current $3,725 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): (a) Facility Wide - On October 4, 2018, the employer did not ensure that employees operating forklifts in the facility were competent to do so by the successful completion of forklift training and evaluation. In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete and must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase, or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $3725
- — Z (S) $7760
1910.212 A01
- Issued
- Dec 4, 2018
- Abate by
- Dec 21, 2018
- Penalty
- Initial $5,174 · Current $2,483 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Production - On October 4, 2018, the employer failed to ensure that guards or methods of guarding were adequate to prevent employees from coming into contact with rotating parts on all of the Mazak CNC equipment. In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete and must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase, or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $2483
- — Z (S) $5174
1910.215 A04
- Issued
- Dec 4, 2018
- Abate by
- Dec 14, 2018
- Penalty
- Initial $6,467 · Current $3,104 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work: (a) Production - On October 4, 2018, the employer did not ensure that all pedestal grinders were equipped with a work rest., including but not limited to the Baldor pedestal grinder and the UtilityBall-Bearing Grinders and Buffers. In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete and must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase, or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $3104
- — Z (S) $6467
1910.178 Q07
- Issued
- Dec 4, 2018
- Abate by
- Dec 14, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service: (a) Facility Wide - On October 4, 2018, the employer failed to ensure that forklifts were being inspected daily before use. In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.215 D01
- Issued
- Dec 4, 2018
- Abate by
- Dec 14, 2018
- Penalty
- Initial $726 · Current $353 Reduced
General-duty citation text
29 CFR 1910.215(d)(1): Wheel(s) on grinding machine(s) were not sounded (ring test) and inspected for damage before mounting: (a) Production - October 4, 2018, the employer did not ensure that a ring test was performed on abrasive wheels prior to mounting on all grinders including but not limited to the Baldor Pedestal Grinder and the Utility Ball-Bearing Grinders and Buffers. In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (O) $352.5
- — Z (O) $726
1910.303 G01 II
- Issued
- Dec 4, 2018
- Abate by
- Dec 14, 2018
- Penalty
- Initial $726 · Current $353 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: (a) Welding Booth 1 - On October 4, 2018, the employer did not ensure that the space around the Federal Pacific transformer was kept clear and not used for storage. In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (O) $352.5
- — Z (O) $726
More inspections at O. C. Keckley Company
View O. C. Keckley Company's full OSHA safety record →
More inspections in this industry (NAICS 332911)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343512315.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.