Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MAVO SYSTEMS WISCONSIN, LLC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of MAVO SYSTEMS WISCONSIN, LLC. in 411 WISCONSIN RIVER DRIVE, PORT EDWARDS, WI 54469 (NAICS 562910). OSHA activity number 343523148.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mavo Systems Wisconsin, LLC. — free Get an email when a new federal OSHA severe-injury report for Mavo Systems Wisconsin, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
411 WISCONSIN RIVER DRIVE
City
PORT EDWARDS
State
WI
ZIP
54469
Mailing
4330 CENTERVILLE ROAD, WHITE BEAR LAKE, MN 55115
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562910
Employees
20
Ownership type
A

5 citations on file for this inspection.

1926.95 A

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 10, 2018
Penalty
Initial $6,467 · Current $6,790

Hazardous substances 9020

29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact.    On or about October 02, 2018 employees were removing asbestos ceiling tiles without eye protection.
Recent events (2)
  • — I (S) $6790
  • — Z (S) $6467

1926.1101 H03 III A

Serious Gravity 10 1 instance 2 exposed
Issued
Dec 10, 2018
Penalty
Initial $9,054 · Current $0 Reduced

Hazardous substances 9020

29 CFR 1926.1101(h)(3)(iii)(A): The employer did not provide a half-mask air-purifying respirator, other than a disposable respirator, equipped with high-efficiency filters, whenever the employee(s) performed Class II and III asbestos jobs where no negative exposure assessment was available:    On or about October 02, 2018 employees were performing class II asbestos abatement without wearing respiratory protection and without an initial negative asbestos exposure assessment for removing asbestos containing ceiling tiles.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9054

1926.1101 J02 III

Serious Gravity 10 1 instance 2 exposed
Issued
Dec 10, 2018
Penalty
Initial $9,054 · Current $0 Reduced

Hazardous substances 9020

29 CFR 1926.1101(j)(2)(i): The employer did not establish a decontamination room or area for employees and equipment, adjacent to the regulated area, consisting of an impermeable drop cloth on the floor or horizontal working surface, for employees engaged in Class I work involving less than 25 linear or 10 square feet of thermal system insulation or surfacing asbestos containing material and for Class II and Class III asbestos work operations where exposures exceed a permissible exposure limit or where there was not negative exposure assessment produced before the operation:    On or about October 02, 2018 employees removed asbestos ceiling tiles without a initial negative exposure assessment and without an equipment room. 29 CFR 1926.1101(j)(2)(iii): For employees engaged in Class I work involving less than 25 linear or 10 square feet of thermal system insulation or surfacing asbestos containing material and for Class II and Class III asbestos work operations where exposures exceed a permissible exposure limit or where there was not negative exposure assessment produced before the operation work clothing was not cleaned with a HEPA vacuum before it was removed:    On or about October 02, 2018 employees removed asbestos ceiling tiles and did not use a HEPA vacuum to clean off their work clothing prior to removal of their work clothing inside the containment.
Recent events (2)
  • — I (S) $6790
  • — Z (S) $9054

1926.1101 M02 I C

Other-than-serious 1 instance 4 exposed
Issued
Dec 10, 2018
Penalty
Initial $9,054 · Current $3,395 Reduced

Hazardous substances 9020

29 CFR 1926.1101(m)(2)(i)(C): The employer did not make available medical examinations and consultations to each employee covered under 29 CFR 1926.1101 (m)(1)(i) at least annually thereafter:    On or about October 02, 2018 employees were performing class II asbestos abatement and the employees previous annual medical examinations were greater than 12 months from October 02, 2018.
Recent events (2)
  • — I (O) $3395
  • — Z (S) $9054

1926.1101 F02 I

Repeat Gravity 10 1 instance 2 exposed
Issued
Dec 10, 2018
Penalty
Initial $18,108 · Current $13,581 Reduced

Hazardous substances 9020

29 CFR 1926.1101(f)(2)(i): The employer with a work operation covered by the asbestos standard did not ensure that a "competent person" conducted an exposure assessment immediately before or at the initiation of the operation to ascertain expected exposures during that operation or workplace:    On or about October 02, 2018 employees removed asbestos containing ceiling tiles and an asbestos exposure assessment was not performed before or at the initiation of removing asbestos containing ceiling tiles.    Mavo Systems, Inc. was previously cited for a violation of this Occupational Safety and Health Standard 29 CFR 1926.1101(f)(2)(i), which was contained in OSHA inspection number 991449, citation number 1, item 1a and was affirmed as a final order on October 31, 2014, with respect to a workplace located at 124 Graham Street, Eau Claire, WI  54703.
Recent events (2)
  • — I (R) $13581
  • — Z (R) $18108

View Mavo Systems Wisconsin, LLC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343523148.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.