Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WEI-CHUAN U.S.A. INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WEI-CHUAN U.S.A. INC. in 7439 LANGTRY ST., HOUSTON, TX 77040 (NAICS 424410). OSHA activity number 343524120.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Wei-Chuan U.S.A. INC. — free Get an email when a new federal OSHA severe-injury report for Wei-Chuan U.S.A. INC. is published. One employer, no account, unsubscribe in one click.
Site address
7439 LANGTRY ST.
City
HOUSTON
State
TX
ZIP
77040
Mailing
7439 LANGTRY ST., HOUSTON, TX 77040
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424410
Employees
19
Ownership type
A

6 citations on file for this inspection.

1910.22 A02

Serious Gravity 1 1 instance 19 exposed
Issued
Nov 29, 2018
Abate by
Dec 24, 2018
Penalty
Initial $6,097 · Current $3,658 Reduced
29 CFR 1910.22(a)(2): The floor of each work area was not maintained in a clean and, to the extent feasible, dry condition.    On or about October 10, 2018 at the freezer section of the warehouse employees were exposed to slip hazards as the floor going into the freezer had accumulated ice.
Recent events (2)
  • — I (S) $3658.2
  • — Z (S) $6097

1910.37 A03

Serious Gravity 1 1 instance 19 exposed
Issued
Nov 29, 2018
Penalty
Initial $6,097 · Current $3,658 Reduced
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:    On or about October 10, 2018 at the rear of the warehouse where employees were exposed to an exit door that was blocked by equipment.
Recent events (2)
  • — I (S) $3658.2
  • — Z (S) $6097

1910.178 L01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 29, 2018
Abate by
Jan 4, 2019
Penalty
Initial $8,130 · Current $4,878 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    On or about October 10, 2018 at the warehouse where employees were required to operate powered electrical pallet jacks without having been trained and evaluated.
Recent events (2)
  • — I (S) $4878
  • — Z (S) $8130

1910.178 P01

Serious Gravity 5 1 instance 19 exposed
Issued
Nov 29, 2018
Abate by
Dec 5, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition(s)     On or about October 10, 2018 throughout the warehouse where employees were exposed to struck-by hazards while operating a Crown forklift SN: 1A489997 that was observed to have worn brakes and defective steering.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 F02

Serious Gravity 5 1 instance 19 exposed
Issued
Nov 29, 2018
Abate by
Dec 13, 2018
Penalty
Initial $10,163 · Current $6,098 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:      On or about October 10, 2018 at the warehouse where three breaker boxes were not labeled to identify each breaker and switch.
Recent events (2)
  • — I (S) $6097.8
  • — Z (S) $10163

1910.305 B01 II

Serious Gravity 5 3 instances 19 exposed
Issued
Nov 29, 2018
Abate by
Dec 13, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    On or about October 10, 2018 at the warehouse where employees were exposed to electrical hazards when using an electrical breaker box and a conduit box that had unused openings.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Wei-Chuan U.S.A. INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343524120.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.