AKRON, OH —
OSHA Inspection: RUSH TRUCK CENTERS OF OHIO, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of RUSH TRUCK CENTERS OF OHIO, INC. in 2697 GILCHRIST RD, AKRON, OH 44305 (NAICS 811111). OSHA activity number 343524740.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RUSH TRUCK CENTERS OF OHIO, INC.
- Site address
- 2697 GILCHRIST RD
- City
- AKRON
- State
- OH
- ZIP
- 44305
- Mailing
- 2697 GILCHRIST RD, AKRON, OH 44305
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811111
- Employees
- 26
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 I
- Issued
- Oct 31, 2018
- Abate by
- Dec 15, 2018
- Penalty
- Initial $11,086 · Current $11,086
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about October 3, 2018, the employer did not ensure energy control procedures were utilized when a diesel truck mechanic performed the service of a manual compression test on a 2012 International 7400 engine.
Recent events (2)
- — I (S) $11086
- — Z (S) $11086
1910.147 D01
- Issued
- Oct 31, 2018
- Abate by
- Dec 15, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): On or about October 3, 2018, employees were exposed to struck by hazards associated with the accidental release of high pressure air during the servicing of a 2012 International 7400 diesel engine. The employer failed to implement energy control application steps as the engine cylinders were not closed or covered to perform the servicing work [per the 1910.147(d)(2) requirement]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3), LOTO device application [(d)(4), dissipation of residual energy [(d)(5)(I)], and verification of isolation [(d)(6), were not implemented to protect employees from machine servicing hazards. Prepare for shutdown [(d)(1)] - ensure authorized employee has knowledge of the type, magnitude, the hazards, and the method or means to control the energy; Shutdown the machine or equipment [(d)(2)]; Machine isolation [(d)(3)] - Physically locate and operate all energy isolation devices that are needed to control the energy to the machine or equipment in such a manner as to isolate the machine or equipment from the energy source(s); LOTO device application [(d)(4)] - Affix a lockout or tagout device to each energy isolating device; Dissipation of residual energy [(d)(5)(i)] - relieve, disconnect, restrain, and otherwise render safe all potentially hazardous stored or residual energy; Verification of isolation [(d)(6)] - Verify that isolation and deenergization of the machine or equipment has been accomplished
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I A
- Issued
- Oct 31, 2018
- Abate by
- Nov 20, 2018
- Penalty
- Initial $11,086 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee had not received training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control: On or about October 3, 2018, the employer did not ensure authorized employees who perform service and maintenance on 2012 International 7400 diesel engine and other machines and equipment used in the mechanic bay received training in the recognition of hazardous energy sources, the type and magnitude of the energy available, and the methods and means necessary for energy isolation and control.
Recent events (2)
- — I (S) $0
- — Z (S) $11086
More inspections in this industry (NAICS 811111)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343524740.