MENTOR, OH —
OSHA Inspection: COMPONENT REPAIR TECHNOLOGIES INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of COMPONENT REPAIR TECHNOLOGIES INC. in 8507 TYLER BLVD., MENTOR, OH 44060 (NAICS 336412). OSHA activity number 343528196.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COMPONENT REPAIR TECHNOLOGIES INC.
- Site address
- 8507 TYLER BLVD.
- City
- MENTOR
- State
- OH
- ZIP
- 44060
- Mailing
- 8507 TYLER BLVD., MENTOR, OH 44060
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336412
- Employees
- 450
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A01
- Issued
- Oct 29, 2018
- Abate by
- May 31, 2019
- Penalty
- Initial $12,934 · Current $9,054 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about October 11, 2018, the employer failed to ensure that employees were protected from hazards such as but not limited to point of operation and rotating parts of equipment such as but not limited to the Bullard Vertical Lathe (Assets 2647, 2591, 2573, 2346, 1130, 1132, 1131, 1127, 2345, 1128, 1124, 1929 and 1129), the Frauenthal CNC Grinder (Assets 1159 and 1150) and the Devlieg Horizontal Mill (Assets 1136, 1698, 1137 and 1141.
Recent events (2)
- — I (S) $9054
- — Z (S) $12934
1910.303 F02
- Issued
- Oct 29, 2018
- Abate by
- Nov 16, 2018
- Penalty
- Initial $5,543 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: On or about October 11, 2018, the employer failed to ensure that an electrical panel/circuit break box (P-11 B) which was located next to Asset #1195 lathe, was properly labeled with identifying information.
Recent events (2)
- — I (O) $0
- — Z (S) $5543
More inspections at Component Repair Technologies INC.
View Component Repair Technologies INC.'s full OSHA safety record →
More inspections in this industry (NAICS 336412)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343528196.