Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: STERICYCLE INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of STERICYCLE INC. in 6240 MCKISSOCK AVENUE, SAINT LOUIS, MO 63147 (NAICS 562211). OSHA activity number 343530507.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Stericycle INC. — free Get an email when a new federal OSHA severe-injury report for Stericycle INC. is published. One employer, no account, unsubscribe in one click.
Establishment
STERICYCLE INC.
Site address
6240 MCKISSOCK AVENUE
City
SAINT LOUIS
State
MO
ZIP
63147
Mailing
6240 MCKISSOCK AVENUE, SAINT LOUIS, MO 63147
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562211
Employees
60
Ownership type
A

17 citations on file for this inspection.

1910.22 A01

Deleted Serious Gravity 5 8 instances 28 exposed
Issued
Nov 16, 2018
Abate by
Jan 7, 2019
Penalty
Initial $11,086 · Current $0 Reduced
29 CFR 1910.22(a)(1):  All places of employment, passageways, storerooms, service rooms, and walking-working surfaces were not kept in a clean, orderly, or in a sanitary condition:  At 6240 McKissock Avenue, St. Louis, MO, on 10/16/18, the walking working surfaces and all places of employment in the following departments were not kept clean, orderly, or in a sanitary condition:  a/  The Bio Tipper located inside of the Bio Department contained biological waste while in storage.  b/  Numerous flexible cords were strewn about on the floor inside of the Waste Water Area.  c/  Black hoses were strewn about on the floor inside of the Compactor Area.  d/  Medical waste was on the floor adjacent to the compactor inside of the Compactor Area.  e/  Wire and cardboard were on the floor adjacent to the compactor inside of the Compactor Area.  f/   Medical waste was on the floor adjacent to the Clave Conveyor.  g/  Components of a broken clave drain housing are on the floor inside of the Clave Dock Area.  h/  Wire strewn about the floor inside of the Warehouse.
Recent events (3)
  • — F (S) $0
  • — C (S) $11086
  • — Z (S) $11086

1910.22 A02

Deleted Serious Gravity 5 3 instances 15 exposed
Issued
Nov 16, 2018
Abate by
Jan 7, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.22(a)(2):  The floor of each workroom was not maintained in a clean and, to the extent feasible, in a dry condition.  Where wet processes were used, drainage was not maintained and, to the extent feasible, dry standing places, such as false floors, platforms, and mats were not provided:    At 6240 McKissock Avenue, St. Louis, MO, the concrete floors inside of the Bio Area, Autoclave Conveyor, Autoclave Dock Area, and the Republic Compactor, were not maintained in a dry condition.  Mats or the equivalent were not provided.  This violation was noted on 10/16/18.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.22 A03

Deleted Serious Gravity 5 3 instances 15 exposed
Issued
Nov 16, 2018
Abate by
Jan 7, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.22(a)(3):  Walking-working surfaces were not maintained free of hazards such as sharp or protruding objects, loose boards, corrosion, leaks, spills, snow, and ice:  At 6240 McKissock Avenue, St. Louis, MO, the concrete walking-working surfaces were not free from protruding metal grating located at the Autoclave Department, Tub Washer Department, and the Republic Compactor.  This violation was noted on 10/16/18.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.28 B03 II

Deleted Serious Gravity 5 2 instances 3 exposed
Issued
Nov 16, 2018
Abate by
Jan 7, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.28(b)(3)(ii):  Each employee was not protected from tripping into or stepping into or through any hole that was less than four (4) feet (1.2 m) above a lower level by covers or guardrail systems:  At 6240 McKissock Avenue, St. Louis, MO, the metal grating located at the Autoclave Department, Tub Washer Department, and the Republic Compactor was missing in many areas where the employees walked.  This violation was noted on 10/16/18.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.37 A03

Deleted Serious Gravity 1 1 instance 3 exposed
Issued
Nov 16, 2018
Abate by
Jan 7, 2019
Penalty
Initial $5,543 · Current $0 Reduced
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:  At 6240 McKissock Avenue, St. Louis, MO, specifically adjacent to the Tub Washer, the pedestrian exit was partially blocked by a 55-gallon container of Lemonex, a hazard chemical.  This violation was noted on 10/16/18.
Recent events (3)
  • — F (S) $0
  • — C (S) $5543
  • — Z (S) $5543

1910.147 C04 I

Deleted Serious Gravity 5 11 instances 3 exposed
Issued
Nov 16, 2018
Abate by
Jan 7, 2019
Penalty
Initial $9,239 · Current $0 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented, and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  At 6240 McKissock Avenue, St. Louis, MO, 10/16/18, specific written procedures were not developed or documented for the following pieces of equipment or machines:  a/ Bondtech Autoclave 1, m/n 1099, s/n 3259-1.  b/ Bondtech Autoclave 2, m/n 1100, s/n 3259-2. c/ Midbrook Tub Washer, s/n 21139. d/ Midbrok Bio Washer, , s/n 21205. e/ Kawaski Robot, m/n E30FB002/RS006L, s/n RS0060093. f/ Tilt Tilt Station. g/ Ingersol Rand Air Compressor Main, UP65-25-145, s/n CBY626389. h/ Ingersol Rand Air Compressor Backup, s/n CBV477081. i/ Hotsy Hotsy 1, m/n 1420SS, s/n H0305-12887. j/ Hotsy Hotsy 2, m/n 99SSS, s/n H0701-72621. k/ Generac 5500 Generator, m/n 59396, s/n 7498050A.
Recent events (3)
  • — F (S) $0
  • — C (S) $9239
  • — Z (S) $9239

1910.147 C04 II

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Nov 16, 2018
Abate by
Jan 7, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):  At 6240 McKissock Avenue, St. Louis, MO, the employer failed to address thermal (heat) as a potential energy source in the specific procedure for the Cleaver Brooks Boiler, m/n CB700200150, s/n OL100964. This violation was noted on 10/16/18.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.212 A01

Deleted Serious Gravity 5 2 instances 3 exposed
Issued
Nov 16, 2018
Abate by
Jan 7, 2019
Penalty
Initial $7,391 · Current $0 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  At 6240 McKissock Avenue, St. Louis, MO, on 10/16/18, specifically inside of the Bio Area and Maintenance Shop respectively, the end of the conveyor system was unguarded exposing employee(s) to the hazard of an in-running nip point.  The rotating parts belonging to a Ryobi Drilling Machine, m/n DP120, s/n C041000073, were unguarded. This violation was noted on 10/16/18.
Recent events (3)
  • — F (S) $0
  • — C (S) $7391
  • — Z (S) $7391

1910.219 C02 I

Deleted Serious Gravity 5 2 instances 3 exposed
Issued
Nov 16, 2018
Abate by
Jan 7, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting:  At 6240 McKissock Avenue, St. Louis, MO, specifically inside of the Bio Washer and Tub Washer Departments, the horizontal shaft powering the conveyor belt was inadequately guarded.  The numerous openings in the belt directly in front of the shaft measured approximately 1" X 2" in size. The unguarded end of this conveyor system was approximately three feet above the concrete floor.  This violation was noted on 10/16/18.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.219 C04 I

Deleted Serious Gravity 5 3 instances 28 exposed
Issued
Nov 16, 2018
Abate by
Jan 7, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft:  At 6240 McKissock Avenue, St. Louis, MO, specifically inside of the Bio Area Department and Conveyor Department, protruding shafts were not guarded.  These unguarded shafts projected more than one half of their diameter and were approximately three feet above the concrete floor.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.243 C01 I B

Deleted Serious Gravity 5 2 instances 3 exposed
Issued
Nov 16, 2018
Abate by
Jan 7, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.243(c)(1)(i)(b): Mounted wheels used in portable operations greater than two (2) inches were unguarded:  At 6240 McKissock Avenue, St. Louis, MO, on 10/16/18, specifically inside of the Maintenance Department, the following portable grinders with six inch wheels were unguarded:   a/  Dewalt Portable Hand Grinder, m/n D28402.   b/ Milwaukee Cordless Grinder.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.303 B01 II

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Nov 16, 2018
Abate by
Jan 7, 2019
Penalty
Initial $12,934 · Current $0 Reduced
29 CFR 1910.303(b)(1)(ii): Electrical equipment was not free from recognized hazards, based on the mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided:  At 6240 McKissock Avenue, St. Louis, MO, specifically the circuit breaker panel box that powers the Republic Compactor, a piece of cardboard was installed to fill in a large gap.  This violation was observed on 10/16/18.
Recent events (3)
  • — F (S) $0
  • — C (S) $12934
  • — Z (S) $12934

1910.303 B07 IV

Deleted Serious Gravity 10 11 instances 15 exposed
Issued
Nov 16, 2018
Abate by
Jan 7, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(7)(iv): There were damaged parts that would adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating:  At 6240 McKissock Avenue, St. Louis, MO, numerous, damaged parts were noted on 10/16/18 at the following locations:  a/ Unsecure receptacle box along the exterior wall of the warehouse. b/ Damaged cover over a receptacle box along the exterior wall of the warehouse. c/ Damaged cover over a junction box along the conveyor system inside of the Bio Department. d/ Damaged cover over a receptacle box mounted to a circular column inside of the Bio Department. e/ Damaged conduit over a conductor that supplies current to the boiler. f/  Damaged conduit over a conductor that supplies current to a motor inside of the Robot Lid Conveyor. g/ Damaged cover to a dual receptacle located inside of the Autoclave Scale Station. h/ Damaged conduit due to a wall being pushed out inside of the Autoclave Scale Station. i/  Damaged receptacle box with a missing cover attached to the Robot Dumper Control Cabinet. j/  Damaged cover attached to the Boiler Makeup Tank Control Panel. k/ Damaged control panel box hanging from below the Autoclave Conveyor.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.303 G01 I

Deleted Serious Gravity 10 4 instances 3 exposed
Issued
Nov 16, 2018
Abate by
Jan 7, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(i): Work space was less than 30 inches wide in front of electric equipment operating at 600 volts, nominal, or less:  At 6240 McKissock Avenue, St. Louis, MO, specifically inside of the Maintenance Shop and Tilt Area, stored materials blocked access to three, 240 volt, circuit breaker panel boxes.  A 480 volt electrical energy disconnect located inside of the Autoclave Area was also partially blocked. This violation was noted on 10/16/18.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.305 B01 II

Deleted Serious Gravity 10 2 instances 3 exposed
Issued
Nov 16, 2018
Abate by
Jan 7, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  At 6240 McKissock Avenue, St. Louis, MO, specifically inside of the Autoclave Dock Area and at the Bio Scale, missing knockouts existed in a power box and a dual receptacle box respectively.  This violation was noted on 10/16/18.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.305 B02 I

Deleted Serious Gravity 10 2 instances 3 exposed
Issued
Nov 16, 2018
Abate by
Jan 7, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:  At 6240 McKissock Avenue, St. Louis, MO, specifically inside of the Robot Dumper Robot Area, the cover belonging to the Robot Dumper Control Cabinet was missing.  The single receptacle belonging to this cabinet was also missing its cover. This violation was noted on 10/16/18.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.334 A02 II

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Nov 16, 2018
Abate by
Jan 7, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service:  At 6240 McKissock Avenue, St. Louis, MO, specifically inside of the Robot Dumper Control Area, the outer insulation belonging to a flexible cord supplying electrical power to the cabinet was missing.  This violation was noted on 10/16/18.