Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: QED

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of QED in 701 OSAGE STREET UNIT 100, DENVER, CO 80204 (NAICS 423610). OSHA activity number 343531935.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch QED — free Get an email when a new federal OSHA severe-injury report for QED is published. One employer, no account, unsubscribe in one click.
Establishment
QED
Site address
701 OSAGE STREET UNIT 100
City
DENVER
State
CO
ZIP
80204
Mailing
1661 W. 3RD AVE, DENVER, CO 80223
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423610
Employees
266
Ownership type
A

1 citation on file for this inspection.

1910.303 B01

Serious Gravity 1 4 instances 12 exposed
Issued
Dec 31, 2018
Abate by
Jan 25, 2019
Penalty
Initial $4,712 · Current $2,800 Reduced
29 CFR 1910.303(b)(1):  Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:      (a)  QED at 701 Osage Street, Unit 100, Denver, CO 80204:  On and before October 2, 2018, the employer failed to provide a workplace free from recognized electrical hazards in that electrical cord connected to the foot control on the Take Up machine in the prep area had exposed inner insulation in several locations due to multiple cuts in the outer sheathing. This condition exposed the employees to the hazard of electrical shock.      (b) QED at 701 Osage Street, Unit 100, Denver, CO 80204:  On and before October 2, 2018, the employer failed to provide a workplace free from recognized electrical hazards in that the electrical cord connected to the control box on the Take Up machine in the prep area had been repaired and its outer insulating sheathing was replaced with electrical tape. This condition exposed the employees to the hazard of electrical shock.      (c)  QED at 701 Osage Street, Unit 100, Denver, CO 80204:  On and before October 2, 2018, the employer failed to provide a workplace free from recognized electrical hazards in that knockout plugs were missing on the control boxes to the following equipment:          1.             Stationary Coiler #4, labeled as 240 Volts.  This condition exposed employees to the hazard of electrical shock and burn.      2.             Stationary Coiler #3, labeled as 208-230 Volts.  This condition exposed employees to the hazard of electrical shock and burn.