OSHA Inspection: US WINDOW SUPPLY & SERVICE INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of US WINDOW SUPPLY & SERVICE INC. in 1325 5TH AVE, NEW YORK, NY 10026 (NAICS 238350). OSHA activity number 343534202.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch US Window Supply & Service INC. — free Get an email when a new federal OSHA severe-injury report for US Window Supply & Service INC. is published. One employer, no account, unsubscribe in one click.
Site address
1325 5TH AVE
City
NEW YORK
State
NY
ZIP
10026
Mailing
246-21 52 AVE, LITTLE NECK, NY 11362
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238350
Employees
5
Ownership type
A

5 citations on file for this inspection.

1926.20 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 3, 2019
Penalty
Initial $2,842 · Current $1,800 Reduced
29 CFR 1926.20(b)(2): The employer did not initiate and maintain a program of frequent and regular inspections made by competent persons at the jobsite:      a)   Safety inspection was not provided; employees were exposed to fall hazard when installing windows, were not equipped with fall protection lifelines, were using an unguarded grinder.       Location: 1325 5th Ave, New York, NY 10026      On or about 10/10/2018      NOTE:  BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $2842

1926.300 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 3, 2019
Penalty
Initial $2,842 · Current $1,800 Reduced
29 CFR 1926.300(b)(1): Power operated tools that were designed to accommodate guards were not equipped with the guards when they were in use, to protect the operator and employees nearby from hazards such as ingoing nip point, rotating parts, flying chips, or sparks:       a)  Employees were exposed to laceration hazard when using the DeWalt grinder (4 inch composite disc) without a blade guard.      Location: 1325 5th Ave, New York, NY 10026      On or about 10/10/2018      NOTE:  BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $2842

1926.501 B14

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 3, 2019
Penalty
Initial $3,978 · Current $2,600 Reduced
29 CFR 1926.501(b)(14): Each employee working on, at, above, or near wall openings was not protected from falling by use of a guardrail system, safety net system, or personal fall arrest system; (when the lower edge of the wall opening is less than 39 inches above the work surface and the fall hazard is greater than 6 feet):      a)  Employee was exposed to 40 ft fall hazard standing halfway out the window sill without fall protection; when replacing windows in the 6 story building.       Location: 1325 5th Ave, New York, NY 10026      On or about 10/10/2018      NOTE:  BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Recent events (2)
  • — I (S) $2600
  • — Z (S) $3978

1926.502 A02

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 3, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.502(a)(2):  The employer did not ensure that all fall protection systems required by this subpart were provided and installed before employees begin the work that necessitates the fall protection:    a) Employer provided fall protection harnesses but no lifelines; employees did not have means to tie off, did not use FP when installing windows exposed to 40 ft fall hazard.    Location: 1325 5th Ave, New York, NY 10026    On or about 10/10/2018    NOTE:  BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.503 A02 II

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 3, 2019
Penalty
Initial $2,842 · Current $1,800 Reduced
29 CFR 1926.503(a)(2)(ii):  The employer did not provide training to employees in the correct procedures for erecting, maintaining, disassembling and inspecting the fall protection systems to be used:    a)  Employer did not provide fall protection training for employees replacing windows in three 6 story apartment buildings; employee was not using fall protection, was exposed to 40 ft fall hazard standing halfway out the window caulking the window frame.     Location: 1325 5th Ave, New York, NY 10026      On or about 10/10/2018      NOTE:  BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $2842

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343534202.