Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: B & B CABINETS AND TRIM

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of B & B CABINETS AND TRIM in 2864 FM 325, LUFKIN, TX 75901 (NAICS 337110). OSHA activity number 343534558.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch B & B Cabinets and Trim — free Get an email when a new federal OSHA severe-injury report for B & B Cabinets and Trim is published. One employer, no account, unsubscribe in one click.
Site address
2864 FM 325
City
LUFKIN
State
TX
ZIP
75901
Mailing
2864 FM 325, LUFKIN, TX 75901
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337110
Employees
11
Ownership type
A

12 citations on file for this inspection.

1910.213 D01

Serious Gravity 5 2 instances 3 exposed
Issued
Jan 18, 2019
Abate by
Jan 28, 2019
Penalty
Initial $3,696 · Current $1,848 Reduced
29 CFR 1910.213(d)(1): Circular handfed crosscut table saw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:    1. On or about October 16, 2018 at the CNC shop, employees were exposed to an amputation hazard while operating a Powermatic cross-cut saw that did not have an adjusting hood enclosing the blade.    2. On or about October 16, 2018 at the assembler shop, employees were exposed to an amputation hazard while operating a Powermatic cross-cut saw  that did not have an adjusting hood enclosing the blade.
Recent events (2)
  • — I (S) $1848
  • — Z (S) $3696

1910.219 D01

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 18, 2019
Penalty
Initial $3,696 · Current $1,848 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):     On or about October 16, 2018 at the CNC shop an employee was exposed to a caught-in or between hazard when working with a Selex Pal CNC router that did not have guards in place around the pulleys.
Recent events (2)
  • — I (S) $1848
  • — Z (S) $3696

1910.219 E03 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 18, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o)(a)  On or about October 16, 2018 at the CNC shop an employee was exposed to a caught-in or between hazard when working with a Selex Pal CNC router that did not have guards in place around the moving belts.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.242 B

Serious Gravity 5 2 instances 1 exposed
Issued
Jan 18, 2019
Abate by
Feb 4, 2019
Penalty
Initial $2,956 · Current $1,478 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    1. On or about October 16, 2018 at the CNC shop where an employee was exposed to struck-by and injection hazards while blowing off equipment without reducing the air pressure below 30 p.s.i.    2. On or about October 16, 2018 at the door shop of the facility where an employee was exposed to struck-by and injection hazards while blowing off equipment without reducing the air pressure below 30 p.s.i.
Recent events (2)
  • — I (S) $1478
  • — Z (S) $2956

1910.303 G02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 18, 2019
Penalty
Initial $3,696 · Current $1,848 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    On or about October 16, 2018 at the CNC shop where an employee was exposed to electrical hazards when an electrical breaker box had its cover removed.
Recent events (2)
  • — I (S) $1848
  • — Z (S) $3696

1910.305 B01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 18, 2019
Abate by
Feb 4, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    On or about October 16, 2018 at the assembler shop where an employee was exposed to electrical hazards when using electrical breaker boxes that had an unused openings.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 F02

Serious Gravity 5 2 instances 1 exposed
Issued
Jan 18, 2019
Abate by
Feb 4, 2019
Penalty
Initial $2,956 · Current $0 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:    On or about October 16, 2018 at the assembler shop and door shop where four breaker boxes were not labeled to identify each breaker and or switch.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2956

1910.1200 E01

Serious Gravity 5 1 instance 11 exposed
Issued
Jan 18, 2019
Abate by
Jan 30, 2019
Penalty
Initial $3,696 · Current $1,848 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:      On or about October 16, 2018, employees were using flammable chemicals such as, but not limited to, lami-lube lubricant spray, high heat canister adhesive and diesel fuel to power forklifts without a written hazard communication program in place.
Recent events (2)
  • — I (S) $1848
  • — Z (S) $3696

1910.1200 H01

Serious Gravity 5 1 instance 11 exposed
Issued
Jan 18, 2019
Abate by
Jan 30, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  On or about October 16, 2018, employees were using flammable chemicals such as, but not limited to, lami-lube lubricant spray, high heat canister adhesive and diesel fuel to power forklifts and had not been trained on the hazards of the chemicals they use.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 G01

Serious Gravity 5 1 instance 11 exposed
Issued
Jan 18, 2019
Abate by
Jan 30, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(1): The employer did not have a material safety data sheet for each hazardous chemical in use:    On or about October 16, 2018,  employer did not have a safety data sheet for the flammable chemicals such as, but not limited to, lami-lube lubricant spray, high heat canister adhesive and diesel fuel available to employees.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 C01

Other-than-serious 1 instance 2 exposed
Issued
Jan 18, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  On or about October 16, 2018 at the assembler shop where the employer had a fire extinguisher blocked by work equipment which was not accessible to employees.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.178 L01 I

Other-than-serious 1 instance 10 exposed
Issued
Jan 18, 2019
Abate by
Feb 13, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    On or about October 16, 2018 at the warehouse, employees were operating forklifts without having been trained and evaluated.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View B & B Cabinets and Trim's full OSHA safety record →