MATTAPAN, MA —
OSHA Inspection: NATIONAL GRID USA SERVICE COMPANY, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of NATIONAL GRID USA SERVICE COMPANY, INC. in BLUE HILL AVENUE & MORTON STREET, MATTAPAN, MA 02126 (NAICS 221210). OSHA activity number 343539078.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NATIONAL GRID USA SERVICE COMPANY, INC.
- Site address
- BLUE HILL AVENUE & MORTON STREET
- City
- MATTAPAN
- State
- MA
- ZIP
- 02126
- Mailing
- 40 SYLVAN ROAD ATTN: SCOTT SOUCY, WALTHAM, MA 02451
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 221210
- Employees
- 5
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.95 A
- Issued
- Apr 5, 2019
- Penalty
- Initial $12,503 · Current $0 Reduced
General-duty citation text
29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact. Jobsite: Employees did not wear chemical protective clothing to provide protection for their arms, legs and torso while handling encapsulating chemicals.
Recent events (3)
- — D (S) $0
- — C (S) $12503
- — Z (S) $12503
1926.102 A01
- Issued
- Apr 5, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation. Jobsite: Employees handling encapsulating chemicals did not wear chemical protective goggles.
Recent events (3)
- — D (S) $0
- — C (S) $0
- — Z (S) $0
1926.651 B04
- Issued
- Apr 5, 2019
- Penalty
- Initial $13,260 · Current $0 Reduced
General-duty citation text
29 CFR 1926.651(b)(4): While the excavation was opened, underground installations were not protected, supported or removed as necessary to safeguard employees: Jobsite: A 'live' secondary gas line was exposed, unsupported and unprotected over the length of the excavation.
Recent events (3)
- — D (S) $0
- — C (S) $13260
- — Z (S) $13260
1926.651 G01 II
- Issued
- Apr 5, 2019
- Penalty
- Initial $13,260 · Current $0 Reduced
General-duty citation text
29 CFR 1926.651(g)(1)(ii): Adequate precautions were not taken to prevent employee exposure to atmospheres containing less than 19.5 percent oxygen and other hazardous atmospheres: Location: Job site Adequate precautions were not taken to prevent employees from being overcome by oxygen deficiency or other hazardous atmospheres.
Recent events (3)
- — D (S) $0
- — C (S) $13260
- — Z (S) $13260
1926.652 A01
- Issued
- Apr 5, 2019
- Penalty
- Initial $10,419 · Current $0 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c). Jobsite: Timber shoring was not designed or installed correctly, thereby exposing employees to a cave-in hazard.
Recent events (3)
- — D (S) $0
- — C (S) $10419
- — Z (S) $10419
1926.651 K02
- Issued
- Apr 5, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.651(k)(2): Where the competent person found evidence of a situation that could result in possible cave-in, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions, exposed employee(s) was/were not removed from the hazardous area until the necessary precautions have been taken to ensure their safety. Location: Jobsite On or about October 16, 2018, employees were allowed to work in an inadequately protected excavation.
Recent events (3)
- — D (S) $0
- — C (S) $0
- — Z (S) $0
1926.652 C
- Issued
- Apr 5, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.652(c): 29 CFR 1926.652(c): Support systems, shield systems, and other protective systems were not designed and constructed in accordance with the requirements of paragraph (c)(1-4); as applicable Location: Jobsite On or about October 16, 2018, employees were exposed to cave-in hazards while working in an excavation where the timber shoring system was not built in accordance with a registered engineer or OSHA excavation standard Appendices A or C.
Recent events (3)
- — D (S) $0
- — C (S) $0
- — Z (S) $0
More inspections at National Grid USA Service Company, INC.
View National Grid USA Service Company, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 221210)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343539078.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.