Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: INTERSTATE HEATING CO., INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of INTERSTATE HEATING CO., INC. in 35510 PABST RD., OCONOMOWOC, WI 53066 (NAICS 238990). OSHA activity number 343539805.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Interstate Heating CO., INC. — free Get an email when a new federal OSHA severe-injury report for Interstate Heating CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
35510 PABST RD.
City
OCONOMOWOC
State
WI
ZIP
53066
Mailing
N53 W24950 S CORPORATE CIRCLE, SUSSEX, WI 53089
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
49
Ownership type
A

2 citations on file for this inspection.

1926.20 B02

Serious Gravity 10 1 instance 1 exposed
Issued
Oct 31, 2018
Abate by
Dec 19, 2018
Penalty
Initial $9,054 · Current $7,700 Reduced
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s):    (a)  A competent person did not ensure that ground conditions (slope, compaction, and firmness) had the ability to support the equipment (JLG 860 SJ aerial lift) that was being used on the job site.
Recent events (2)
  • — I (S) $7700
  • — Z (S) $9054

1926.453 B02 V

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 31, 2018
Abate by
Nov 6, 2018
Penalty
Initial $6,467 · Current $0 Reduced
29 CFR 1926.453(b)(2)(v): A body belt with lanyard attached to the boom or basket was not worn by employee(s) working from an aerial lift:    (a)  An employee operating a JLG 860 SJ aerial lift was not protected from a fall/thrown hazard by using a safety harness and lanyard attached to the lift.