Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: LIFTECH EQUIPMENT COMPANIES, LLC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of LIFTECH EQUIPMENT COMPANIES, LLC. in 2820 CURRY ROAD, SCHENECTADY, NY 12301 (NAICS 423830). OSHA activity number 343541215.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Liftech Equipment Companies, LLC. — free Get an email when a new federal OSHA severe-injury report for Liftech Equipment Companies, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
2820 CURRY ROAD
City
SCHENECTADY
State
NY
ZIP
12301
Mailing
6847 ELLICOTT DRIVE, EAST SYRACUSE, NY 13057
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423830
Employees
22
Ownership type
A

6 citations on file for this inspection.

1910.147 C04 I

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Dec 10, 2018
Abate by
Jan 14, 2019
Penalty
Initial $7,484 · Current $0 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  (a) On and before 10/18/2018, at facility, for the employee performing maintenance on hydraulics, engines, and brakes on equipment such as, but not limited to forklifts, backhoes, and skid steers.  The employer did not develop procedures for the control of hazardous energy.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7484

1910.179 J02 III

Other-than-serious 1 instance 1 exposed
Issued
Dec 10, 2018
Abate by
Jan 14, 2019
Penalty
Initial $7,484 · Current $1,513 Reduced
29 CFR 1910.179(j)(2)(iii): Monthly inspections of hooks, with a certification record which includes the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier, of the hook inspected, were not performed:    (a) On and before 10/18/2018, at facility, for the employee using the 3 ton crane and 3 ton hoist to lift pull a cylinder on a mast.  The employer did not perform monthly inspections.
Recent events (2)
  • — I (O) $1513
  • — Z (S) $7484

1910.179 J02 IV

Other-than-serious 1 instance 1 exposed
Issued
Dec 10, 2018
Abate by
Jan 14, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.179(j)(2)(iv): Monthly inspections of hoist chains, with a certification record which includes the date of inspection, the signature of the person who performed the inspection and an identifier of the chain which was inspected, were not performed:    (a) On and before 10/18/2018, at facility, for the employee using the 3 ton crane and 3 ton hoist to lift pull a cylinder on a mast.  The employer did not perform monthly inspections.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 10, 2018
Abate by
Dec 18, 2018
Penalty
Initial $7,484 · Current $7,484
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  (a) On and before 10/18/2018, at facility, for the employee drilling a plate.  The employer did not have a guard on the drill press.
Recent events (2)
  • — I (S) $7484
  • — Z (S) $7484

1910.303 G01

Serious Gravity 1 1 instance 1 exposed
Issued
Dec 10, 2018
Abate by
Dec 14, 2018
Penalty
Initial $4,490 · Current $4,490
29 CFR 1910.303(g)(1):  Sufficient access and working space was not provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment:  a) On or about 10/18/2018, at facility, the employer had blocked electrical panel with oil drums making it difficult to access in the event of an emergency.
Recent events (2)
  • — I (S) $4490
  • — Z (S) $4490

1910.305 A02 I

Other-than-serious 1 instance 1 exposed
Issued
Dec 10, 2018
Abate by
Jan 14, 2019
Penalty
Initial $4,490 · Current $1,513 Reduced
29 CFR 1910.305(a)(2)(i): Temporary electrical power and lighting installation(s) 600 volts, nominal, or less were used in prohibited manners:    a) On and before 10/18/2018, at facility, the employer had a yellow extension cord zip-tied to provide power to the solenoid on an air compressor and a lead cord to provide power to the pump on the outdoor fuel tank.
Recent events (2)
  • — I (O) $1513
  • — Z (S) $4490

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343541215.