Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: THE SELINSKY FORCE, LLC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of THE SELINSKY FORCE, LLC. in 3900 BIXBY ROAD, GROVEPORT, OH 43125 (NAICS 811310). OSHA activity number 343544417.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The Selinsky Force, LLC. — free Get an email when a new federal OSHA severe-injury report for The Selinsky Force, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
3900 BIXBY ROAD
City
GROVEPORT
State
OH
ZIP
43125
Mailing
5365 EAST CENTER DRIVE NE SUITE C, CANTON, OH 44721
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811310
Employees
10
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 I

Deleted Serious Gravity 10 2 instances 4 exposed
Issued
Feb 5, 2019
Abate by
Feb 25, 2019
Penalty
Initial $9,282 · Current $0 Reduced
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.   a. On or about October 13, 2018, located in the INF Department on the Grinder Line at Amsted Rail in Groveport, Ohio, lockout/tagout procedures were not utilized when employees were changing out a pneumatic cylinder on FR-75 unpender and roller pins from FR-64 pneumatic upender, thereby exposing the employees to caught-in hazards.
Recent events (3)
  • — J (S) $0
  • — C (S) $9282
  • — Z (S) $9282

1910.147 D

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Feb 5, 2019
Abate by
Feb 25, 2019
Penalty
Initial $9,282 · Current $0 Reduced
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence:  a. On or about October 13, 2018, located in the INF Department on the Grinder Line at Amsted Rail in Groveport, Ohio, employees were exposed to machine caught-in hazards when removing roller pins from, FR-64, a pneumatic upender. The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.   On October 13, 2018, employees were removing the pins on FR-64 upender when one of the employees tripped an electronic photo-sensing eye causing the machine to actuate while an employee was at the location of its pneumatic ram causing crushing injuries to the employee.
Recent events (3)
  • — J (S) $0
  • — C (S) $9282
  • — Z (S) $9282

1910.147 F03 II D

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Feb 5, 2019
Abate by
Feb 25, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(f)(3)(ii)(D): Each authorized employee shall affix a personal lockout or tagout device to the group lockout device, group lockbox, or comparable mechanism when he or she begins work, and shall remove those devices when he or she stops working on the machine or equipment being serviced or maintained.  a. On or about October 13, 2018, located in the INF Department at Amsted Rail in Groveport, Ohio, the employer did not ensure employees were protected from machine caught-in hazards while performing a group lockout/tagout activity when removing roller pins from FR-64, a pneumatic upender. Three employees were involved in the pin removal without their locks affixed to energy isolating devices.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.147 D06

Serious 1 instance 2 exposed
Issued
Feb 5, 2019
Abate by
May 11, 2020
Penalty
Initial $0 · Current $9,282
29 CFR 1910.147(d)(6): Verification of isolation. Prior to starting work on machines or equipment that have been locked out or tagged out, the authorized employee shall verify that isolation and deenergization of the machine or equipment have been accomplished.  a. On or about October 13, 2018, located in the INF Department on the Grinder Line at Amsted Rail in Groveport, Ohio, the employer did not ensure all authorized employees performing a cylinder change on FR-75 verified the isolation and deenergization of the upender.
Recent events (3)
  • — J (S) $9282
  • — C (O) $0
  • — Z (O) $0

View The Selinsky Force, LLC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343544417.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.