Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GOODWIN BROS. CONSTRUCTION CO.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of GOODWIN BROS. CONSTRUCTION CO. in NEAR: 5380 WESTWOOD DRIVE, WELDON SPRING, MO 63304 (NAICS 237110). OSHA activity number 343548194.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Goodwin Bros. Construction CO. — free Get an email when a new federal OSHA severe-injury report for Goodwin Bros. Construction CO. is published. One employer, no account, unsubscribe in one click.
Site address
NEAR: 5380 WESTWOOD DRIVE
City
WELDON SPRING
State
MO
ZIP
63304
Mailing
4885 BAUMGARTNER ROAD, SAINT LOUIS, MO 63129
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
100
Ownership type
A

3 citations on file for this inspection.

1926.651 C02

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 20, 2019
Penalty
Initial $9,282 · Current $13,260
29 CFR 1926.651(c)(2):  A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:     The employer is failing to protect employees from struck-by and engulfment hazards. This was most recently documented on or about October 16, 2018 at a jobsite near 5380 Westwood Drive, Weldon Springs, Missouri.  The employer did not provide or ensure that a safe means of egress was located in the trench/excavation. Employees were installing a twenty inch (20") forced water main pipe in a trench/excavation measuring approximately six feet five inches (6'.5") in depth, Nine feet (9') in width and fifty six feet (56') in length.
Recent events (3)
  • — J (S) $13260
  • — C (S) $9282
  • — Z (S) $9282

1926.651 K02

Serious Gravity 10 1 instance 4 exposed
Issued
Mar 20, 2019
Abate by
Apr 8, 2019
Penalty
Initial $9,282 · Current $13,260
29 CFR 1926.651(k)(2):  Where the competent person found evidence of a situation that could result in a possible cave-in, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions, exposed employees were not removed from the hazardous area until the necessary precautions had been taken to ensure their safety    The employer is failing to protect employees from struck-by and engulfment hazards. This was most recently documented on or about October 16, 2018 at a jobsite near 5380 Westwood Drive, Weldon Springs, Missouri.     (a) The competent person authorized employees to enter an unprotected excavation with a Type B soil.  The trench measured approximately six feet five inches (6'.5") in depth, Nine feet (9') in width and fifty six feet (56') in length.  No protective system was located on the jobsite.    (b) The competent person authorized employees to enter the excavation without providing a unimpeded safe access and egress path.
Recent events (3)
  • — J (S) $13260
  • — C (S) $9282
  • — Z (S) $9282

1926.652 A01

Serious Gravity 10 1 instance 4 exposed
Issued
Mar 20, 2019
Penalty
Initial $106,078 · Current $13,260 Reduced
29 CFR 1926.652(a)(1):  Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section:    The employer is failing to protect employees from struck-by and engulfment hazards associated with trenching and excavations. This was most recently documented on or about October 16, 2018 at a jobsite located at or near 5380 Westwood Drive, Weldon Springs, Missouri 63367.  Employees were installing approximately four thousand feet (4000') of twenty inch (20") inch forced water main pipe running parallel with Westwood Drive. The employer did not provide or require the use of a protective system in a trench/excavation measuring approximately six feet, five inches (6'.5") in depth, Nine feet (9') in width and fifty six feet (56') in length.
Recent events (3)
  • — J (S) $13260
  • — C (W) $106078
  • — Z (W) $106078

View Goodwin Bros. Construction CO.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343548194.