GARLAND, TX ·
OSHA Inspection: PLASTIPAK PACKAGING, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PLASTIPAK PACKAGING, INC. in 3201 MILLER PARK ROAD, GARLAND, TX 75042 (NAICS 326160). OSHA activity number 343549242.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PLASTIPAK PACKAGING, INC.
- Site address
- 3201 MILLER PARK ROAD
- City
- GARLAND
- State
- TX
- ZIP
- 75042
- Mailing
- 3201 MILLER PARK NORTH ROAD, GARLAND, TX 75042
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326160
- Employees
- 284
- Ownership type
- Private (A)
Citations
1 citation on file for this inspection.
1910.307 C
- Issued
- Jan 25, 2019
- Abate by
- Mar 14, 2019
- Penalty
- Initial $13,260 · Current $0 Reduced
M110
General-duty citation text
29 CFR 1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location: In the Grinding Room-Electrical equipment in a Class II, Division II location were not approved for a Class II, Division II location or safe for a Class II, Division II location, on or about October 22, 2018: Instance (a): General purpose outlet boxes in the Grinding Room were not dust-tight and approved or safe for a Class II, Division II location. Instance (b): Pulse-Bat and Dayton shop vacuums were not dust-tight and approved or safe for a Class II, Division II location. Instance (c): General Duty Circuit breaker boxes were not dust-tight and approved or safe for a Class II, Division II location. Instance (d): Electric motors were not dust-tight and approved or safe for a Class II, Division II location.
Recent events (3)
- · F (S) $0
- · C (S) $13260
- · Z (S) $13260
More inspections at Plastipak Packaging, INC.
View Plastipak Packaging, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326160)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343549242.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.