Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: SALVUCCI MASONRY CO., INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SALVUCCI MASONRY CO., INC. in 50-150 CAUSEWAY STREET, BOSTON, MA 02114 (NAICS 238140). OSHA activity number 343567095.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Salvucci Masonry CO., INC. — free Get an email when a new federal OSHA severe-injury report for Salvucci Masonry CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
50-150 CAUSEWAY STREET
City
BOSTON
State
MA
ZIP
02114
Mailing
686 LINCOLN STREET, WALTHAM, MA 02451
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
23
Ownership type
A

9 citations on file for this inspection.

1926.20 B02

Deleted Serious Gravity 10 2 instances 23 exposed
Issued
Apr 10, 2019
Abate by
Apr 18, 2019
Penalty
Initial $8,354 · Current $0 Reduced
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s)    Location:  Jobsite    Workers were exposed to fall and other hazards at a jobsite where a competent person had not adequately inspected the work areas to ensure that they were free from hazards
Recent events (2)
  • — I (S) $0
  • — Z (S) $8354

1926.451 F03

Serious Gravity 10 1 instance 10 exposed
Issued
Apr 10, 2019
Abate by
Apr 18, 2019
Penalty
Initial $0 · Current $8,354
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity:    Location:  Jobsite    One worker fell from, and others were exposed to fall and other hazards ,from a scaffold that lacked adequate access and fall protection which had not been inspected prior to the start of the work shift.
Recent events (2)
  • — I (S) $8354
  • — Z (S) $0

1926.451 B04

Deleted Serious Gravity 10 4 instances 10 exposed
Issued
Apr 10, 2019
Abate by
Apr 18, 2019
Penalty
Initial $8,354 · Current $0 Reduced
29 CFR 1926.451(b)(4): Each end of a platform, not cleated or otherwise restrained by hooks or equivalent means, did not extend over the centerline of its support at least 6 inches (15 cm)  Location:  Jobsite  Employees were exposed to fall hazards of up to and greater than 25 feet from tubular welded frame scaffolding to the ground below where planks which did not extend more than 6 inches over the supports were not cleated or otherwise secured.
Recent events (2)
  • — I (S) $0
  • — Z (S) $8354

1926.451 C01

Serious Gravity 10 1 instance 10 exposed
Issued
Apr 10, 2019
Abate by
Apr 18, 2019
Penalty
Initial $8,354 · Current $8,354
29 CFR 1926.451(c)(1): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) were not restrained from tipping by guying, tying, bracing, or equivalent means, as set forth in subparagraphs (i) - (iii) of this paragraph.    Location:  Jobsite    Workers were exposed to the hazards of scaffolding collapse, where a tubular welded frame scaffold exceeded the 4:1 base to height ratio and was not restrained with guys, ties or braces.
Recent events (2)
  • — I (S) $8354
  • — Z (S) $8354

1926.451 C02

Serious Gravity 5 18 instances 10 exposed
Issued
Apr 10, 2019
Abate by
Apr 18, 2019
Penalty
Initial $5,967 · Current $0 Reduced
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames,  or uprights did not bear on base plates, mud sills or other adequate firm foundation:    Location:  Jobsite    Workers were exposed to the hazards of scaffolding collapse where a tubular welded frame scaffold did not bear on base plates.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5967

1926.451 E01

Serious Gravity 10 3 instances 10 exposed
Issued
Apr 10, 2019
Abate by
Apr 18, 2019
Penalty
Initial $8,354 · Current $8,292 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access.    Location:  Jobsite    One worker fell and other workers were exposed, where safe access to upper working levels of a tubular welded frame scaffold, was not used or provided.
Recent events (2)
  • — I (S) $8292
  • — Z (S) $8354

1926.451 E08

Serious Gravity 10 2 instances 10 exposed
Issued
Apr 10, 2019
Abate by
Apr 18, 2019
Penalty
Initial $8,354 · Current $0 Reduced
29 CFR 1926.451(e)(8): Direct access to or from another surface was used when the scaffold was more than 14 inches (36 cm) horizontally and/or 24 inches (61 cm) vertically from the other surface:    Location:  Jobsite    Workers were exposed to fall hazards of over 16' from an upper working level to the concrete floor below, where there was a gap of at least 20 inches between the scaffold and the upper working level.
Recent events (2)
  • — I (S) $0
  • — Z (S) $8354

1926.451 G01 VI

Serious Gravity 10 4 instances 10 exposed
Issued
Apr 10, 2019
Abate by
Apr 18, 2019
Penalty
Initial $8,354 · Current $0 Reduced
29 CFR 1926.451(g)(1)(vi): Each employee performing overhand bricklaying operations from a supported scaffold was not protected from falling from all open sides and ends of the scaffold (except at the side next to the wall being laid) by the use of a personal fall arrest system or guardrail system (with minimum 200 pound toprail capacity).    Location:  Jobsite    Workers were exposed to falls from tubular welded frame scaffolding where guardrails, mid-rails and end-rails had not been installed at various points on the scaffold.
Recent events (2)
  • — I (S) $0
  • — Z (S) $8354

1926.501 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 10, 2019
Penalty
Initial $8,354 · Current $0 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.    Location:  Jobsite    Workers were exposed to fall hazards of over 16' from an upper floor to a floor below where fall protection was not used or provided.
Recent events (2)
  • — I (S) $0
  • — Z (S) $8354

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343567095.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.