Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VEOLIA NORTH AMERICA, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of VEOLIA NORTH AMERICA, LLC in 700 E. JONES ST., MILWAUKEE, WI 53207 (NAICS 562219). OSHA activity number 343571469.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Veolia North America, LLC — free Get an email when a new federal OSHA severe-injury report for Veolia North America, LLC is published. One employer, no account, unsubscribe in one click.
Site address
700 E. JONES ST.
City
MILWAUKEE
State
WI
ZIP
53207
Mailing
700 E. JONES ST., MILWAUKEE, WI 53207
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562219
Employees
8000
Ownership type
A

1 citation on file for this inspection.

1910.147 D

Serious Gravity 10 1 instance 4 exposed
Issued
Mar 29, 2019
Abate by
Apr 24, 2019
Penalty
Initial $13,260 · Current $13,260
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):   (a) On or about October 31, 2018, and times prior, at the workplace located at 700 E. Jones St., Milwaukee, WI 53207, D&D Building #258, 2nd floor, the employer did not ensure employees implemented energy control procedures prior to sub-contracted employees entering the drum of Dryer #5 to perform blade replacement operations. The machine was not isolated from all energy sources prior to sub-contracted employees engaging in these servicing and maintenance activities.   As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lock-out/tag-out device application [1910.147(d)(4)], dissipation of residual energy [1910.147(d)(5)(i)], and verification of isolation [1910.147(d)(6)], were not implemented to protect employees from the unexpected energization, startup, or release of stored energy during machine servicing and maintenance activities.
Recent events (1)
  • — Z (S) $13260

View Veolia North America, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343571469.