MILWAUKEE, WI —
OSHA Inspection: VEOLIA NORTH AMERICA, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of VEOLIA NORTH AMERICA, LLC in 700 E. JONES ST., MILWAUKEE, WI 53207 (NAICS 562219). OSHA activity number 343571469.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VEOLIA NORTH AMERICA, LLC
- Site address
- 700 E. JONES ST.
- City
- MILWAUKEE
- State
- WI
- ZIP
- 53207
- Mailing
- 700 E. JONES ST., MILWAUKEE, WI 53207
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 562219
- Employees
- 8000
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.147 D
- Issued
- Mar 29, 2019
- Abate by
- Apr 24, 2019
- Penalty
- Initial $13,260 · Current $13,260
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): (a) On or about October 31, 2018, and times prior, at the workplace located at 700 E. Jones St., Milwaukee, WI 53207, D&D Building #258, 2nd floor, the employer did not ensure employees implemented energy control procedures prior to sub-contracted employees entering the drum of Dryer #5 to perform blade replacement operations. The machine was not isolated from all energy sources prior to sub-contracted employees engaging in these servicing and maintenance activities. As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lock-out/tag-out device application [1910.147(d)(4)], dissipation of residual energy [1910.147(d)(5)(i)], and verification of isolation [1910.147(d)(6)], were not implemented to protect employees from the unexpected energization, startup, or release of stored energy during machine servicing and maintenance activities.
Recent events (1)
- — Z (S) $13260
More inspections at Veolia North America, LLC
View Veolia North America, LLC's full OSHA safety record →
More inspections in this industry (NAICS 562219)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343571469.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.