ABILENE, TX —
OSHA Inspection: BWJ METAL WORKS, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BWJ METAL WORKS, LLC in 3125 EAST HWY 80, ABILENE, TX 79601 (NAICS 332322). OSHA activity number 343578977.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BWJ METAL WORKS, LLC
- Site address
- 3125 EAST HWY 80
- City
- ABILENE
- State
- TX
- ZIP
- 79601
- Mailing
- 3125 EAST HWY 80, ABILENE, TX 79601
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332322
- Employees
- 99
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.107 C06
- Issued
- Apr 29, 2019
- Abate by
- May 23, 2019
- Penalty
- Initial $5,304 · Current $3,182 Reduced
General-duty citation text
29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations. On or about October 31, 2018, at the facility employees were exposed to electrical and/or burn hazards when electrical outlets used to energize the sprayer were not intrinsically safe.
Recent events (2)
- — I (S) $3182.4
- — Z (S) $5304
1910.184 H01
- Issued
- Apr 29, 2019
- Abate by
- May 23, 2019
- Penalty
- Initial $5,304 · Current $3,182 Reduced
General-duty citation text
29 CFR 1910.184(h)(1): Natural and synthetic fiber-rope slings did not have permanently affixed and legible identification markings stating the rated capacity for the type(s) of hitch(es) used and the angle upon which it was based, type of fiber material, and the number of legs if more than one: On or about October 31, 2018, at the facility, the slings used to move metal sections of silos did not have legible identification markings.
Recent events (2)
- — I (S) $3182.4
- — Z (S) $5304
1910.184 H05 III
- Issued
- Apr 29, 2019
- Abate by
- May 23, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.184(h)(5)(iii): Natural or synthetic fiber rope sling(s) with broken or cut fibers were not immediately removed from service: a) At the facility, damaged rope slings with broken and cut fibers were not immediately removed from service.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.215 A04
- Issued
- Apr 29, 2019
- Abate by
- May 23, 2019
- Penalty
- Initial $5,304 · Current $3,182 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rests. On offhand grinding machines, work rests shall be used to support the work. They shall be of rigid construction and designed to be adjustable to compensate for wheel wear. Work rests shall be kept adjusted closely to the wheel with a maximum opening of one-eighth inch to prevent the work from being jammed between the wheel and the rest, which may cause wheel breakage. The work rest shall be securely clamped after each adjustment. The adjustment shall not be made with the wheel in motion. On or about October 31, 2018, at the facility, the employer did not ensure that the work rest on the Delta bench grinder was not less than 1/8 of an inch, exposing employees to struck-by hazards.
Recent events (2)
- — I (S) $3182.4
- — Z (S) $5304
1910.334 A02 I
- Issued
- Apr 29, 2019
- Abate by
- May 23, 2019
- Penalty
- Initial $7,956 · Current $4,774 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord- and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence for possible internal damage (such as pinched or crushed outer jacket): On or about October 31, 2018, at the facility, the DeWalt hand grinder, Serial #WVE402 the outer sheathing of the cord was damaged and covered in black tape.
Recent events (2)
- — I (S) $4773.6
- — Z (S) $7956
1910.305 B01 II
- Issued
- Apr 29, 2019
- Abate by
- May 23, 2019
- Penalty
- Initial $3,978 · Current $2,387 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed: On or about October 31, 2018, at the facility, the employer did not ensure electrical cabinets or boxes did not have missing knockouts including but not limited to: a) North wall square D breaker box missing knockouts; b) Center west side GE breaker box missing knockouts; c) Southwest corner of detail shop Eaton safety cut off missing knockouts; d) Center wall GE 480 safety switch missing knockouts; e) Southeast wall by shear missing knockouts; f) Center of shop Siemens I-T_E enclosed switch missing knockouts;
Recent events (2)
- — I (S) $2386.8
- — Z (S) $3978
1910.305 G01 III
- Issued
- Apr 29, 2019
- Abate by
- May 23, 2019
- Penalty
- Initial $5,304 · Current $3,182 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iii): Unless specifically permitted in paragraph (g)(1)(I) of this section, flexible cords and cables may not be used as a substitute for the fixed wiring of a structure: On or about October 31, 2018, at the facility, the employer used flexible cords as permanent wiring such as, but not limited to: a) South central wall by plasma machine; b) Northwest central wall by grating saw; c) center of shop.
Recent events (2)
- — I (S) $3182.4
- — Z (S) $5304
1910.305 G02 III
- Issued
- Apr 29, 2019
- Abate by
- May 23, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws: On or about October 31, 2018, at this facility, employees were exposed to electrical hazards when flexible cables were not provided strain relief.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.334 A03 I
- Issued
- Apr 29, 2019
- Abate by
- May 23, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(3)(i): A flexible cord used with grounding type equipment shall contain an equipment grounding conductor: On or about October 31, 2018, at this facility employees performing work task with a Makita electric hand tool that was connected to flexible cords that was missing a ground pin.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at BWJ Metal Works, LLC
View BWJ Metal Works, LLC's full OSHA safety record →
More inspections in this industry (NAICS 332322)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343578977.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.