OSHA Inspection: JOSE ANGEL GONZALEZ PEREZ

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JOSE ANGEL GONZALEZ PEREZ in 8625 WINKLER DR., HOUSTON, TX 77017 (NAICS 238160). OSHA activity number 343580494.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Jose Angel Gonzalez Perez — free Get an email when a new federal OSHA severe-injury report for Jose Angel Gonzalez Perez is published. One employer, no account, unsubscribe in one click.
Site address
8625 WINKLER DR.
City
HOUSTON
State
TX
ZIP
77017
Mailing
6310 DUMFRIES DR #142, HOUSTON, TX 77096
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
2
Ownership type
A

2 citations on file for this inspection.

1926.501 B11

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 21, 2018
Penalty
Initial $3,880 · Current $3,880
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems  a) At building #4, employees working approximately 30 feet above the ground were not protected from falling by any type of a fall protection system.
Recent events (1)
  • — Z (S) $3880

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 21, 2018
Abate by
Dec 18, 2018
Penalty
Initial $1,885 · Current $1,885
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder:  a)  At the northwest side of an apartment complex, the extension ladder used for access to the roof was not secured and did not extend three feet above the edge of the roof, exposing employees to fall hazards.