CHICAGO, IL —
OSHA Inspection: KCP METAL FABRICATIONS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of KCP METAL FABRICATIONS, INC. in 5475 N. NORTHWEST HIGHWAY, CHICAGO, IL 60630 (NAICS 332322). OSHA activity number 343583027.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KCP METAL FABRICATIONS, INC.
- Site address
- 5475 N. NORTHWEST HIGHWAY
- City
- CHICAGO
- State
- IL
- ZIP
- 60630
- Mailing
- 5475 N. NORTHWEST HIGHWAY, CHICAGO, IL 60630
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332322
- Employees
- 36
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 D
- Issued
- Dec 14, 2018
- Abate by
- Jan 31, 2019
- Penalty
- Initial $9,054 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): (a) Forming Department - On November 6, 2018, employees were exposed to machine hazards associated with moving parts during set-up, on equipment such as but not limited to the Cone 900 press brake, the Cone 1600 press brake and the HURCO PN-30.12 press brake. The employer failed to implement energy control application steps as LOTO devices were not applied to the electrical disconnect [per the 1910.147(d)(4) requirements]. As a result, the remaining applicable energy control elements, involving dissipation of residual energy [(d)(5)(I)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards. In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete and must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase, or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $5000
- — Z (S) $9054
1910.212 A01
- Issued
- Dec 14, 2018
- Abate by
- Feb 28, 2019
- Penalty
- Initial $9,054 · Current $5,800 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation; (a) Forming Department - On or about October 26, 2018, the employer failed to ensure that guarding was provided on equipment such as but not limited to the Hurco PN-30-12 press brake and the Coast One Cone 900 press brake to protect employees from the rotating parts and nip points. An employee suffered a finger amputation while operating the Coast One Cone 900 press brake. In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete and must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase, or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $5800
- — Z (S) $9054
1910.212 B
- Issued
- Dec 14, 2018
- Abate by
- Dec 27, 2018
- Penalty
- Initial $726 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: (a) Forming Department - On November 6, 2018, the employer did not ensure that the Cone 900 press brake was securely anchored to prevent walking or moving. In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (O) $0
- — Z (O) $726
More inspections at KCP Metal Fabrications, INC.
View KCP Metal Fabrications, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332322)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343583027.