O FALLON, MO ·
OSHA Inspection: BRECKENRIDGE MATERIALS COMPANY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BRECKENRIDGE MATERIALS COMPANY in 1440 W. TERRA LANE, O FALLON, MO 63366 (NAICS 327320). OSHA activity number 343584207.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BRECKENRIDGE MATERIALS COMPANY
- Site address
- 1440 W. TERRA LANE
- City
- O FALLON
- State
- MO
- ZIP
- 63366
- Mailing
- P.O. BOX 440459, SAINT LOUIS, MO 63144
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327320
- Employees
- 16
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.147 C04 II B
- Issued
- Nov 15, 2018
- Abate by
- Jan 4, 2019
- Penalty
- Initial $8,315 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedure did not clearly and specifically specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: On or about 11/05/2018, Breckenridge Materials Company dba Breckenridge of OFallon, located at 1440 W Terra Lane, OFallon, MO, did not have specific procedures to control hazardous energy for the Kemco System. This system had electrical, water (pressure), and natural gas energy sources.
Recent events (2)
- · I (O) $1000
- · Z (S) $8315
1910.147 C06 I
- Issued
- Nov 15, 2018
- Abate by
- Jan 4, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: On or about 11/05/2018, Breckenridge Materials Company dba Breckenridge of OFallon, located at 1440 W Terra Lane, OFallon, MO, did not conduct a timely periodic inspection(s) of their Energy Control (LO/TO) Program. The last periodic inspection was dated July 10, 2014.
Recent events (2)
- · I (O) $0
- · Z (S) $0
1910.178 L01 I
- Issued
- Nov 15, 2018
- Abate by
- Jan 4, 2019
- Penalty
- Initial $8,315 · Current $7,315 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): On or about 11/05/2018, Breckenridge Materials Company dba Breckenridge of OFallon, located at 1440 W Terra Lane, OFallon, MO, had an employee operating a forklift without having completed the required training. The operator had never attended training and evaluation for the JCB powered industrial truck.
Recent events (2)
- · I (S) $7315
- · Z (S) $8315
More inspections in this industry (NAICS 327320)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343584207.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.