Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,991Inspections Most recent open 2026-08-24 Last loaded 2026-08-27

OSHA Inspection: D AND C EXTREME INDUSTRIES, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of D AND C EXTREME INDUSTRIES, INC. in 1985 VICTOR PLACE, COLORADO SPRINGS, CO 80916 (NAICS 811111). OSHA activity number 343584546.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch D and C Extreme Industries, INC. for free Get an email when a new federal OSHA severe-injury report for D and C Extreme Industries, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1985 VICTOR PLACE
City
COLORADO SPRINGS
State
CO
ZIP
80916
Mailing
1985 VICTOR PLACE, COLORADO SPRINGS, CO 80916
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811111
Employees
6
Ownership type
Private (A)

13 citations on file for this inspection.

1910.28 B01 I

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 20, 2018
Abate by
Nov 27, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2m) or more above a lower level was protected from falling by guardrail systems, safety net system, or personal fall arrest system:   a) On or about November 6, 2018, and at times prior, employees were exposed to fall hazards of approximately 8 feet while they store and gather materials at the mezzanine of the shop area. The employees were not protected with a fall protection system.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.212 A01

Serious Gravity 5 2 instances 3 exposed
Issued
Nov 20, 2018
Abate by
Nov 28, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a) On or about November 6, 2018 and at times prior, employees were exposed to serious hazards while using a vertical band saw. The belt and pulley of the band saw was not provided with a guard cover.  b) On or about November 6, 2018 and at times prior, employees were exposed to serious hazards while using a bench sander. The sanding belt and drive pulley was not provided with a guard cover.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.212 A03 II

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 20, 2018
Abate by
Nov 27, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  a) On or about November 6, 2018 and at times prior, employees were exposed to serious hazards while using a vertical band saw. The blade of the band saw had an exposed opening of 7 inch and was not guarded.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.215 A04

Serious Gravity 1 1 instance 3 exposed
Issued
Nov 20, 2018
Abate by
Nov 27, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:  a) On or about November 6, 2018 and at times prior, employees were exposed to serious hazards while using a bench grinder. The work rest of the bench grinder was missing and did not have an opening of one eight inch.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.215 B09

Serious Gravity 1 1 instance 3 exposed
Issued
Nov 20, 2018
Abate by
Nov 27, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  a) On or about November 6, 2018 and at times prior, employees were exposed to serious hazards while using a bench grinder. The adjustable tongue was missing on the bench grinder. The adjustable tongue of the bench grinder did not have an opening of one fourth inch.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 B01 I

Serious Gravity 1 1 instance 3 exposed
Issued
Nov 20, 2018
Abate by
Nov 27, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(i): Openings through which conductors entered cutout boxes, cabinets, or fittings were not effectively closed:  a) On or about November 6, 2018 and at times prior, employees were exposed to electrical shock from an electrical outlet box at the shop area. The opening of the electrical outlet box was not effectively closed.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 B02 I

Serious Gravity 1 1 instance 3 exposed
Issued
Nov 20, 2018
Abate by
Nov 27, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:  a) On or about November 6, 2018 and at times prior, employees were exposed to electrical shock from an electrical outlet box at the shop area. The electrical outlet box was not provided with an electrical outlet cover.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 G02 II

Serious Gravity 1 1 instance 3 exposed
Issued
Nov 20, 2018
Abate by
Nov 27, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap:  a) On or about November 6, 2018 and at times prior, employees were exposed to electrical shocks from flexible cords used at the shop area. The flexible cords were spliced, repaired and did not have continuous lengths.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 G02 III

Serious Gravity 1 1 instance 3 exposed
Issued
Nov 20, 2018
Abate by
Nov 27, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  a) On or about November 6, 2018 and at times prior, employees were exposed to electrical shocks from flexible cords used at the shop area. The flexible cords were not provided with strain relief.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.37 B06

Other-than-serious 1 instance 3 exposed
Issued
Nov 20, 2018
Abate by
Nov 27, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color:  a) On or about November 6, 2018 and at times prior, an exit sign located at the east side of the shop area was not illuminated. The exit sign would be difficult to see in the event of a fire emergency.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.157 C01

Other-than-serious 1 instance 3 exposed
Issued
Nov 20, 2018
Abate by
Nov 27, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:   a) On or about November 6, 2018, and at times prior, several portable fire extinguishers were located in the shop area. The locations of the portable fire extinguishers were not identified with a "fire extinguisher" sign.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.157 E03

Other-than-serious 1 instance 3 exposed
Issued
Nov 20, 2018
Abate by
Nov 27, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:  a) On or about November 6, 2018, and at times prior, three portable fire extinguishers in the workplace were not annually maintained. The fire extinguishers were last annually maintained on 2011.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.157 G01

Other-than-serious 1 instance 3 exposed
Issued
Nov 20, 2018
Abate by
Nov 27, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting:   a) On or about November 6, 2018, and at times prior, employees were required to use portable fire extinguishers in the event of a fire in the shop area. The employees were not provided with training on the use and the hazards involved with the incipient stage of firefighting.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343584546.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.