Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FERMATA CORPORATION in 317 E 37TH STREET, BOISE, ID 83714 (NAICS 323111). OSHA activity number 343589784.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FERMATA CORPORATION
- Site address
- 317 E 37TH STREET
- City
- BOISE
- State
- ID
- ZIP
- 83714
- Mailing
- 317 E 37TH STREET, BOISE, ID 83714
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323111
- Employees
- 20
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C01
- Issued
- Mar 7, 2019
- Abate by
- Jul 18, 2019
- Penalty
- Initial $1,932 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) Bindery: On or about November 8, 2019 and at times prior thereto; Hans Muller AG, Saddlestitcher, Type 221, NBR 925842. b) Press room: On or about November 8, 2019 and at times prior thereto; Komori Lithrone 28 Offset Press. Note* Abatement certification IS required for this item.
Recent events (2)
- · I (S) $1000
- · Z (S) $1932
1910.147 C06 I
- Issued
- Mar 7, 2019
- Abate by
- Jul 18, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Bindery: On or about November 8, 2019 and at times prior thereto; Hans Muller AG, Saddlestitcher, Type 221, NBR 925842. b) Press room: On or about November 8, 2019 and at times prior thereto; Komori Lithrone 28. Offset Press. Note* Abatement certification IS required for this item.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.212 A02
- Issued
- Mar 7, 2019
- Abate by
- Jun 5, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(2): Machine guard(s) on machine(s) were so installed that they offered accident hazards in themselves: Production floor: On or about November 8, 2018, and at times prior thereto; Hans Muller AG, Saddlestitcher, Type 221, NBR 925842, had three cracked guards which could result in slips, trips, or falls if clothes or tools are caught on the guards. Note* Abatement certification IS required for this item.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 323111)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343589784.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.