OSHA Inspection: THORP EQUIPMENT, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of THORP EQUIPMENT, INC. in N14160 COUNTY RD. M, THORP, WI 54771 (NAICS 332312). OSHA activity number 343595146.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Thorp Equipment, INC. — free Get an email when a new federal OSHA severe-injury report for Thorp Equipment, INC. is published. One employer, no account, unsubscribe in one click.
Site address
N14160 COUNTY RD. M
City
THORP
State
WI
ZIP
54771
Mailing
N14160 COUNTY RD. M, THORP, WI 54771
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
161
Ownership type
A

6 citations on file for this inspection.

1910.305 G02 III

Serious Gravity 5 2 instances 4 exposed
Issued
Feb 4, 2019
Abate by
Feb 19, 2019
Penalty
Initial $5,217 · Current $3,652 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:    (a) North and south welding areas; Strain relief was not provided on the plug ends of welder cords and flexible cord sets (extension cords).
Recent events (2)
  • — I (S) $3651.9
  • — Z (S) $5217

1910.334 A02 I

Serious Gravity 5 2 instances 4 exposed
Issued
Feb 4, 2019
Abate by
Feb 19, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  (a) South welding area; Plug ends on portable fans were not visually inspected for damage, such as missing grounding pins.  (b) North and south welding areas; Flexible cord sets (extension cords) were not visually inspected for damage, such as a lack of strain relief.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.334 A02 II

Serious Gravity 5 2 instances 4 exposed
Issued
Feb 4, 2019
Abate by
Feb 19, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(ii): When there was a defect or evidence of damage that could expose an employee to injury, the defective or damaged item was not removed from service until the repairs and tests necessary to render the electric equipment safe had been made:  (a) South welding area; Portable fans with missing ground pins were not removed from service until the plug ends were repaired or replaced.  (b) North and south welding areas; Flexible cord sets (extension cords) with strain relief issues were not removed from service until the plug ends were repaired or replaced.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.334 A03 II

Serious Gravity 5 2 instances 4 exposed
Issued
Feb 4, 2019
Abate by
Feb 19, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(3)(ii): Attachment plugs and receptacles were connected or altered in a manner which prevented proper continuity of the electric equipment grounding conductor at the point where plugs were attached to receptacles:  (a) South welding area; Grounding pins were missing from the plug end of portable fan cords.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 A02 XI

Other-than-serious 1 instance 2 exposed
Issued
Feb 4, 2019
Abate by
Feb 19, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.305(a)(2)(xi): Cable assemblies and flexible cords shall be supported in place with supports in the form of staples, cables ties, straps, or similar type fittings installed so as not to cause damage.  (a) North welding area, near electrical panel 2D; Welding wire was used to support a flexible cord in a welding bay.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G01 IV A

Other-than-serious 1 instance 2 exposed
Issued
Feb 4, 2019
Abate by
Feb 19, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  (a) North welding area, near electrical panel 2D; A flexible cord set (extension cord) was used in place of permanent wiring to supply electricity for a two-gang junction box that was mounted to the wall.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Thorp Equipment, INC.'s full OSHA safety record →