OSHA Inspection: CINDER BUTTE CATTLE CO., LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CINDER BUTTE CATTLE CO., LLC in 6730 W 129 N, IDAHO FALLS, ID 83402 (NAICS 112130). OSHA activity number 343603353.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cinder Butte Cattle CO., LLC for free Get an email when a new federal OSHA severe-injury report for Cinder Butte Cattle CO., LLC is published. One employer, no account, unsubscribe in one click.
Site address
6730 W 129 N
City
IDAHO FALLS
State
ID
ZIP
83402
Mailing
6730 W 129 N, IDAHO FALLS, ID 83402
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
112130
Employees
12
Ownership type
A

5 citations on file for this inspection.

1926.651 K01

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 31, 2019
Abate by
Feb 27, 2019
Penalty
Initial $3,031 · Current $1,516 Reduced
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions:    a) Cattle pen area: On November 14, 2018 and at times prior thereto an inspection of a trench was not conducted by a competent  person to determine the soil type and the proper protective system needed before allowing employees to work in a 6.6 foot deep trench.      Note) Certification of corrective action is required for this item.
Recent events (2)
  • · I (S) $1515.5
  • · Z (S) $3031

1926.652 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 31, 2019
Abate by
Feb 27, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c);  a) Cattle pen area: On November 14, 2018 and at times prior thereto employees worked in a trench without a cave-in protective system in place.  The trench measured 6.3 to 6.6 feet deep and 3 .5 feet wide.  Note) Certification of corrective action is required for this item.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1928.57 B01 III

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 31, 2019
Abate by
Feb 27, 2019
Penalty
Initial $3,031 · Current $1,516 Reduced
29 CFR 1928.57(b)(1)(iii): Power take-off driven equipment was not guarded to protect against employee contact with positively driven rotating members of the power drive system:    a) Farm:  On November 14, 2018 and at times prior thereto the shield for the power take off shaft on the #2 feed mixer was broken.  This exposed employees to an 11 inch section of the rotating shaft.            Note) Certification of corrective action is required for this item.
Recent events (2)
  • · I (S) $1515.5
  • · Z (S) $3031

1910.132 D01

Other-than-serious 1 instance 1 exposed
Issued
Jan 31, 2019
Abate by
Feb 27, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards were present, or were likely to be present, which necessitated the use of personal protective equipment:  a) Maintenance shop: On November 14, 2018 and at times prior thereto the employer had not conducted a workplace hazard assessment to determine if a respiratory protection program was needed.  Employees used half and full face respirators provided by the employer, while performing various painting activities.        Note) Certification of corrective action is required for this item.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.1200 E01

Other-than-serious 1 instance 1 exposed
Issued
Jan 31, 2019
Abate by
Feb 27, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): The employers did not develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met (Agriculture Reference: 1928.21(a)(5)):  a) Maintenance shop: On November 14, 2018 and at times prior thereto the employer did not provide employees with training and information on proper use and personal protection when using hazardous chemicals in the workplace.  Safety data sheets were not available for chemicals and products which included, but may not be limited to, Klean Strip spray gun paint remover, zero rust, and Buff primer sealer.       Note ) Certification of corrective action is required for this item.