HARRISON CITY, PA ·
OSHA Inspection: GABRIEL PERFORMANCE PRODUCTS, LLC
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of GABRIEL PERFORMANCE PRODUCTS, LLC in 408 MANOR HARRISON CITY ROAD, HARRISON CITY, PA 15636 (NAICS 325211). OSHA activity number 343605432.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GABRIEL PERFORMANCE PRODUCTS, LLC
- Site address
- 408 MANOR HARRISON CITY ROAD
- City
- HARRISON CITY
- State
- PA
- ZIP
- 15636
- Mailing
- 408 MANOR HARRISON CITY ROAD, HARRISON CITY, PA 15636
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325211
- Employees
- 35
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.134 F02
- Issued
- Feb 11, 2019
- Abate by
- Mar 18, 2019
- Penalty
- Initial $5,115 · Current $3,300 Reduced
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting face piece respirators were not fit tested whenever a different respirator face piece (size, style, model or make) was used: a) In the Facility, on or about November 16, 2019 - An employee designated as a Kettleman was not fit tested with a full face respirator when that respirator was worn infrequently at the facility.
Recent events (2)
- · I (S) $3300
- · Z (S) $5115
1910.134 K05 I
- Issued
- Feb 11, 2019
- Abate by
- Mar 18, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k)(5)(i): Retraining was not conducted when changes in the workplace or the type of respirator rendered previous training obsolete: a) In the Facility, on or about November 16, 2019 - An employee designated as a Kettleman, who uses a full face respirator in the workplace, was not provided training on that type of respirator.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.134 M02
- Issued
- Feb 11, 2019
- Abate by
- Mar 18, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(m)(2): The employer did not establish a record of the qualitative or quantitative fit test administered to employees: a) In the Facility, on or about November 16, 2019 - The employer did not establish an adequate record of fit tests which were administered to employees who are required to use respirators in the workplace. ABATEMENT NOTE: Respirator fit test records must contain the following: 1. The name or identification of the employee tested; 2. Type of fit test performed; 3. Specific make, model, style and size of respirator tested; 4. Date of test; and 5. The pass/fail results for qualitative fit tests or the fit factor and strip chart recording or other recording of the test results for quantitative fit tests.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections at Gabriel Performance Products, LLC
View Gabriel Performance Products, LLC's full OSHA safety record →
More inspections in this industry (NAICS 325211)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343605432.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.