Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: GABRIEL PERFORMANCE PRODUCTS, LLC

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of GABRIEL PERFORMANCE PRODUCTS, LLC in 408 MANOR HARRISON CITY ROAD, HARRISON CITY, PA 15636 (NAICS 325211). OSHA activity number 343605432.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Gabriel Performance Products, LLC for free Get an email when a new federal OSHA severe-injury report for Gabriel Performance Products, LLC is published. One employer, no account, unsubscribe in one click.
Site address
408 MANOR HARRISON CITY ROAD
City
HARRISON CITY
State
PA
ZIP
15636
Mailing
408 MANOR HARRISON CITY ROAD, HARRISON CITY, PA 15636
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325211
Employees
35
Ownership type
Private (A)

3 citations on file for this inspection.

1910.134 F02

Serious Gravity 1 1 instance 1 exposed
Issued
Feb 11, 2019
Abate by
Mar 18, 2019
Penalty
Initial $5,115 · Current $3,300 Reduced
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting face piece respirators were not fit tested whenever a different respirator face piece (size, style, model or make) was used:    a)  In the Facility, on or about November 16, 2019 - An employee designated as a Kettleman was not fit tested with a full face respirator when that respirator was worn infrequently at the facility.
Recent events (2)
  • · I (S) $3300
  • · Z (S) $5115

1910.134 K05 I

Serious Gravity 1 1 instance 1 exposed
Issued
Feb 11, 2019
Abate by
Mar 18, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(5)(i): Retraining was not conducted when changes in the workplace or the type of respirator rendered previous training obsolete:   a)  In the Facility, on or about November 16, 2019 - An employee designated as a Kettleman, who uses a full face respirator in the workplace, was not provided training on that type of respirator.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.134 M02

Serious Gravity 1 1 instance 1 exposed
Issued
Feb 11, 2019
Abate by
Mar 18, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.134(m)(2):  The employer did not establish a record of the qualitative or quantitative fit test administered to employees:   a)  In the Facility, on or about November 16, 2019 - The employer did not establish an adequate record of fit tests which were administered to employees who are required to use respirators in the workplace.    ABATEMENT NOTE:  Respirator fit test records must contain the following:  1.  The name or identification of the employee tested;  2.  Type of fit test performed;  3.  Specific make, model, style and size of respirator tested;  4.  Date of test; and   5.  The pass/fail results for qualitative fit tests or the fit factor and strip chart recording or other recording of the test results for quantitative fit tests.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

View Gabriel Performance Products, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343605432.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.