Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: D.J. BEARDSLEY & SONS, INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of D.J. BEARDSLEY & SONS, INC. in 1 HOPKINS ROAD, WILLIAMSVILLE, NY 14221 (NAICS 238210). OSHA activity number 343605499.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch D.J. Beardsley & Sons, INC. — free Get an email when a new federal OSHA severe-injury report for D.J. Beardsley & Sons, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1 HOPKINS ROAD
City
WILLIAMSVILLE
State
NY
ZIP
14221
Mailing
150 W. MILL STREET, CASTILE, NY 14427
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
2
Ownership type
A

2 citations on file for this inspection.

1926.404 B01 II

Serious Gravity 1 1 instance 1 exposed
Issued
Feb 13, 2019
Penalty
Initial $1,642 · Current $1,232 Reduced
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection:   a) On or about 11/9/18, at the site of Williamsville, NY. A hole drill, that drew power through a flexible cord plugged into wall receptacles, lacked the ground fault circuit interrupters for personal protection.   NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $1231.5
  • — Z (S) $1642

1926.405 A02 II J

Other-than-serious 1 instance 1 exposed
Issued
Feb 13, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.405(a)(2)(ii)(J): Extension cord sets used with portable electric tools and appliances were not designed for hard or extra-hard usage:    a) On or about 11/9/18, at the site of Williamsville, NY. A black extension cord set with power strip, used to power tools, was not rated for hard or extra-hard usage.   NO ABATEMENT CERTIFICATION REQUIRED