Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: UNITED ACOUSTICS INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of UNITED ACOUSTICS INC. in 15200 N. WESTERN AVE., EDMOND, OK 73013 (NAICS 238310). OSHA activity number 343609251.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch United Acoustics INC. — free Get an email when a new federal OSHA severe-injury report for United Acoustics INC. is published. One employer, no account, unsubscribe in one click.
Site address
15200 N. WESTERN AVE.
City
EDMOND
State
OK
ZIP
73013
Mailing
204 N.W. 132ND, OKLAHOMA CITY, OK 73114
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238310
Employees
5
Ownership type
A

3 citations on file for this inspection.

1926.300 B01

Other-than-serious 1 instance 1 exposed
Issued
Dec 6, 2018
Abate by
Dec 14, 2018
Penalty
Initial $3,696 · Current $1,500 Reduced
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use:       On or about November 16, 2018, at the job site a power chop saw was provided with a guard but during use the guard was kept open by a screw installed by employees.  This exposed employees to amputation hazard.
Recent events (2)
  • — I (O) $1500
  • — Z (S) $3696

1926.453 B02 IV

Other-than-serious 1 instance 2 exposed
Issued
Dec 6, 2018
Abate by
Dec 14, 2018
Penalty
Initial $2,956 · Current $1,500 Reduced
29 CFR 1926.453(b)(2)(iv): Employee(s) working in an aerial lift were sitting or climbing on the edge of the basket:       On or about September 16, 2018, at the job site an employee was observed climbing on the railing of a telescoping boom lift raised to approximately 10 feet high.  This exposed the employee to a fall hazard.
Recent events (2)
  • — I (O) $1500
  • — Z (S) $2956

1926.453 B02 V

Other-than-serious 1 instance 2 exposed
Issued
Dec 6, 2018
Abate by
Dec 14, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift: Note:  As of January 1, 1998, subpart M of this part (1926.502(d)) provides that body belts are not acceptable as part of a personal fall arrest system.  The use of a body belt in a tethering system or in a restraint system is acceptable and is regulated:       On or about November 16, 2018, at the job site employees were observed working in a telescoping boom lift installing metal channels to a building approximately 10 feet above the ground.  The employees were wearing fall protection harness but not tying off.  The employees were exposed to fall hazards.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

View United Acoustics INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343609251.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.