NORTH SYRACUSE, NY —
OSHA Inspection: CARLTON MATHEWS ROOFING AND SIDING
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of CARLTON MATHEWS ROOFING AND SIDING in 5383 BEAR ROAD, NORTH SYRACUSE, NY 13212 (NAICS 238160). OSHA activity number 343609392.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CARLTON MATHEWS ROOFING AND SIDING
- Site address
- 5383 BEAR ROAD
- City
- NORTH SYRACUSE
- State
- NY
- ZIP
- 13212
- Mailing
- 1251 FAY STREET, FULTON, NY 13069
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 8
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 B05 II
- Issued
- Apr 23, 2019
- Abate by
- Apr 29, 2019
- Penalty
- Initial $4,376 · Current $4,376
General-duty citation text
29 CFR 1926.451(b)(5)(ii): The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilivered end: a) At the jobsite, at the rear of the building, on or about 11/15/18: Employees worked from a ladder jack scaffold where one end of the 20 foot pick extended over one support by over 40 inches, exposing workers to a fall of 12 feet to ground.
Recent events (1)
- — Z (S) $4376
1926.451 F07
- Issued
- Apr 23, 2019
- Abate by
- Apr 29, 2019
- Penalty
- Initial $4,376 · Current $4,376
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration: a) At the jobsite, at the rear of the building, on or about 11/15/18: Employees worked from a ladder jack scaffold where workers were exposed to a fall of 12 feet to ground at one end of the scaffold without fall protection, where that end of the scaffold extended out over its support by over 40 inches, and where the pick was constructed and used where that working level was not level. Conditions observed indicated that the scaffold was not erected under the supervision of a competent person.
Recent events (1)
- — Z (S) $4376
1926.451 G01
- Issued
- Apr 23, 2019
- Abate by
- Apr 29, 2019
- Penalty
- Initial $4,376 · Current $4,376
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level. a) At the jobsite, at the rear of the building, on or about 11/15/18: Employees worked from a ladder jack scaffold where workers were exposed to a fall of 12 feet to ground at one end of the scaffold.
Recent events (1)
- — Z (S) $4376
1926.501 B13
- Issued
- Apr 23, 2019
- Abate by
- Apr 29, 2019
- Penalty
- Initial $29,172 · Current $29,172
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) At the jobsite, on the roof, on or about 11/15/18: Employees worked on a 10:12 pitch roof, with a ground to eave height of 9 feet and 14 feet without fall protection of any kind.
Recent events (1)
- — Z (W) $29172
1926.1053 B01
- Issued
- Apr 23, 2019
- Abate by
- Apr 29, 2019
- Penalty
- Initial $29,172 · Current $29,172
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) At the jobsite, accessing the roof, on or about 11/15/18: Employees worked on a 10:12 pitch roof, and accessed that roof by an extension ladder that did not extend at least 3 feet above the upper landing.
Recent events (1)
- — Z (W) $29172
More inspections at Carlton Mathews Roofing and Siding
View Carlton Mathews Roofing and Siding's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343609392.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.