Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RIVERCREST ENTERPRISES

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RIVERCREST ENTERPRISES in #2 & 4 WATER STREET, MASSENA, NY 13662 (NAICS 238990). OSHA activity number 343609640.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rivercrest Enterprises — free Get an email when a new federal OSHA severe-injury report for Rivercrest Enterprises is published. One employer, no account, unsubscribe in one click.
Site address
#2 & 4 WATER STREET
City
MASSENA
State
NY
ZIP
13662
Mailing
6 RIVERCREST DRIVE, MASSENA, NY 13662
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
12
Ownership type
A

4 citations on file for this inspection.

1926.304 H01

Serious Gravity 5 1 instance 12 exposed
Issued
Apr 2, 2019
Penalty
Initial $3,031 · Current $400 Reduced
29 CFR 1926.304(h)(1): Each circular crosscut table saw was not guarded by a hood which completely enclosed that portion of the saw blade above the table and that portion of the saw above the material being cut:    a)  At the jobsite, on or about 11/16/18:  Employees were using a DeWalt table saw to cut dimensional lumber for rough interior framing and carpentry where that saw was not guarded.
Recent events (3)
  • — J (S) $400
  • — C (S) $3031
  • — Z (S) $3031

1926.403 B01 I

Serious Gravity 5 3 instances 12 exposed
Issued
Apr 2, 2019
Abate by
Apr 10, 2019
Penalty
Initial $3,031 · Current $400 Reduced
29 CFR 1926.403(b)(1)(i): Safety of equipment was not determined on the basis of suitability of the equipment for an identified purpose as evidenced by listing, labeling, or certification for that identified purpose.    a)  At the jobsite, on or about 11/16/18:  Power was supplied to the workspace with a hardwired duplex outlet box that was designed to be mounted to a solid surface and was not.    b)  At the jobsite, on or about 11/16/18:  Power was supplied to the workspace with a hardwired quad outlet box that was designed to be mounted to a solid surface and was not.      c)  At the jobsite, on or about 11/16/18:  Power was supplied to the workspace utilizing an office style power strip that was not designed for construction use.
Recent events (3)
  • — J (S) $400
  • — C (S) $3031
  • — Z (S) $3031

1926.403 B01 II

Serious Gravity 5 1 instance 12 exposed
Issued
Apr 2, 2019
Abate by
Apr 10, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.403(b)(1)(ii): Safety of equipment was not determined on the basis of mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided:    a)  At the jobsite, on or about 11/16/18:  Supplied power to the worksite floor was provided with spliced line where those splices were held together with wire nuts and were subject to being stepped on or contacted and disengaged.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.403 I02 I

Serious Gravity 5 1 instance 12 exposed
Issued
Apr 2, 2019
Abate by
Apr 10, 2019
Penalty
Initial $3,789 · Current $400 Reduced
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph:      a)  At the jobsite, on or about 11/16/18:  Employees were exposed to live electrical circuits where a cover was missing from an opening in the electrical panel.
Recent events (3)
  • — J (S) $400
  • — C (S) $3789
  • — Z (S) $3789

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343609640.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.