WASHINGTON, DC ·
OSHA Inspection: BANYAI CONSTRUCTION CORP.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BANYAI CONSTRUCTION CORP. in 5201 KLINGLE STREET NW, WASHINGTON, DC 20015 (NAICS 238160). OSHA activity number 343614145.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BANYAI CONSTRUCTION CORP.
- Site address
- 5201 KLINGLE STREET NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20015
- Mailing
- 21108 WALKLEY HILL PLACE, ASHBURN, VA 20148
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1926.102 A01
- Issued
- Apr 9, 2019
- Abate by
- Apr 15, 2019
- Penalty
- Initial $3,978 · Current $2,200 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation. a) On or about November 20, 2018; throughout the site; employees were exposed to a struck by hazard while operating pneumatic nail guns without wearing eye protection. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- · I (S) $2200
- · Z (S) $3978
1926.501 B13
- Issued
- Apr 9, 2019
- Abate by
- Apr 15, 2019
- Penalty
- Initial $3,978 · Current $2,200 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b) a) On or about November 20, 2018, roof area; employees were working on a residential roof without wearing fall protection exposing them to an estimated 30-35-foot fall hazard. b) On or about November 20, 2018, roof area; employees wearing fall protection were not tied off, exposing them to an estimated 30-35-foot fall hazard. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- · I (S) $2200
- · Z (S) $3978
1926.1053 B01
- Issued
- Apr 9, 2019
- Abate by
- Apr 15, 2019
- Penalty
- Initial $3,978 · Current $2,600 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On or about November 20, 2018; front area; the ladder used to access the roof area was extended eighteen inches above the roof exposing employees to an estimated 30 foot fall. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- · I (S) $2600
- · Z (S) $3978
1926.1053 B06
- Issued
- Apr 9, 2019
- Abate by
- Apr 15, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(6): Unsecured ladder(s) were used on surfaces that were not stable and level: a) On or about November 20, 2019; Front of residential home; employees were using an extension ladder to access the roof area that was not secured from displacement exposing employees to an estimated 30-foot fall hazard; ladder was set on uneven dirt surface. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.503 B01
- Issued
- Apr 9, 2019
- Abate by
- Apr 15, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. a) On or about November 20, 2018; throughout the site; the employer had not certified the fall protection training to employees that may be exposed to fall hazards 6-feet or greater as well as methods to protect themselves while conducting their assigned duties. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 238160)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343614145.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.