WASHINGTON, DC ·
OSHA Inspection: HAKEZ CONSTRUCTON LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HAKEZ CONSTRUCTON LLC in 11 SEATON PL NW, WASHINGTON, DC 20010 (NAICS 238130). OSHA activity number 343614160.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HAKEZ CONSTRUCTON LLC
- Site address
- 11 SEATON PL NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20010
- Mailing
- 4013 91 STREET AVE, SPRINGDALE, MD 20774
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 4
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1926.404 B01 II
- Issued
- May 6, 2019
- Abate by
- May 13, 2019
- Penalty
- Initial $1,932 · Current $0 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection. a) On or about November 14, 2018; roof area; employees were operating portable equipment such as but not limited to Makita saws that were not protected by a ground-fault circuit interrupter exposing them to a shock hazard. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (3)
- · C (S) $1932
- · F (S) $0
- · Z (S) $1932
1926.405 B02
- Issued
- May 6, 2019
- Abate by
- May 13, 2019
- Penalty
- Initial $2,898 · Current $0 Reduced
General-duty citation text
29 CFR 1926.405(b)(2): In energized installations, each outlet box did not have a cover, faceplate, or fixture canopy: a) On or about November 14, 2018; throughout site; employees plugged portable equipment into electrical outlet boxes that were missing faceplates. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (3)
- · C (S) $2898
- · F (S) $0
- · Z (S) $2898
1926.501 B13
- Issued
- May 6, 2019
- Abate by
- May 10, 2019
- Penalty
- Initial $3,978 · Current $3,978
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about November 14, 2018; second floor, employees installing windows were not wearing fall protection to prevent them from falling 12-feet to ground level. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
- · C (S) $3978
- · F (S) $3978
- · Z (S) $3978
1926.503 B01
- Issued
- May 6, 2019
- Abate by
- May 13, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. a) On or about November 14, 2018; throughout the site; the employer had not certified the fall protection training to employees that may be exposed to fall hazards 6-feet or greater as well as methods to protect themselves while conducting their assigned duties. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (3)
- · C (O) $0
- · F (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 238130)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343614160.