Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: BRI UTILITY CONSTRUCTION, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of BRI UTILITY CONSTRUCTION, INC. in RIDGEDALE DR & PINEHURST RD, SNELLVILLE, GA 30078 (NAICS 237110). OSHA activity number 343614194.

Watch BRI Utility Construction, INC. — free Get an email when a new federal OSHA severe-injury report for BRI Utility Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
RIDGEDALE DR & PINEHURST RD
City
SNELLVILLE
State
GA
ZIP
30078
Mailing
P.O. BOX 2025, DACULA, GA 30019
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
35
Ownership type
A

4 citations on file for this inspection.

1926.21 B02

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $9282.00 · Current $6504.00 Reduced
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury.      On or about November 19, 2018 at Ridgedale Drive and Pinehurst Road, Snellville, Georgia  employees working in an unprotected trench had not been trained to recognize and avoid the unsafe conditions of the trench they were working in.
Recent events (2)
  • — I (O) $6504
  • — Z (S) $9282

1926.651 C02

Other-than-serious 1 instance 3 exposed
Issued
Penalty
Initial $9282.00 · Current $6504.00 Reduced
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:(a    On or about November 19, 2018 at Ridgedale Drive and Pinehurst Road, Snellville, Georgia during the excavation to a new sanitary sewer line, the employer failed to provide a safe means of access/egress in the trench approximately 20 feet deep and 30 feet wide.
Recent events (2)
  • — I (O) $6504
  • — Z (S) $9282

1926.652 A01

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $9282.00 · Current $6504.00 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c).    On or about November19, 2018 at Ridgedale Drive and Pinehurst Road, Snellville, Georgia workers in a trench approximately 20 feet deep were not protected from cave-in hazards when the trench was not sloped or a trench box provided.
Recent events (2)
  • — I (S) $6504
  • — Z (S) $9282

1926.651 J02

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $9282.00 · Current $6504.00 Reduced
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.      On or about November 19, 2018 at Ridgedale Drive and Pinehurst Road, Snellville, Georgia where employees were installing a new sanitary sewer line in a trench approximately 20 feet were exposed to a trench collapse when the spoil pile was placed on the edge of the trench.
Recent events (2)
  • — I (S) $6504
  • — Z (S) $9282

View BRI UTILITY CONSTRUCTION, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343614194.