CORPUS CHRISTI, TX ·
OSHA Inspection: VALERO REFINING-TEXAS, L.P.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of VALERO REFINING-TEXAS, L.P. in 1147 CANTWELL LANE, CORPUS CHRISTI, TX 78407 (NAICS 324110). OSHA activity number 343615142.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VALERO REFINING-TEXAS, L.P.
- Site address
- 1147 CANTWELL LANE
- City
- CORPUS CHRISTI
- State
- TX
- ZIP
- 78407
- Mailing
- PO BOX 9370, CORPUS CHRISTI, TX 78469
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 324110
- Employees
- 755
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.147 C04 I
- Issued
- May 8, 2019
- Abate by
- May 28, 2019
- Penalty
- Initial $13,260 · Current $13,260
03201080148019572460
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: At this establishment, employees were exposed to struck-by, caught-in or-between, amputation, electrical and to toxic atmospheric hazards when performing service and/or maintenance of equipment. Energy control procedures with all required elements were not established and utilized by the employer for controlling hazardous energies on pumps and other facility equipment.
Recent events (2)
- · I (O) $13260
- · Z (S) $13260
1910.147 C06 I
- Issued
- May 8, 2019
- Abate by
- May 28, 2019
- Penalty
- Initial $13,260 · Current $0 Reduced
03201080148019572460
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: At this establishment, employees were exposed to struck-by, caught-in or-between, amputation, electrical and to toxic atmospheric hazards when performing service and/or maintenance of equipment. The inspections of the energy control procedures were not conducted at least annually by the employer.
Recent events (2)
- · I (S) $0
- · Z (S) $13260
1910.147 C07 I
- Issued
- May 8, 2019
- Abate by
- May 28, 2019
- Penalty
- Initial $0 · Current $0
03201080148019572460
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: At this establishment, the employer did not adequately train employees on Lockout/Tagout program and procedures for isolating hazardous energies for the water injection pump. This exposed employees to struck-by, caught-in or-between, amputation, electrical and to toxic atmospheric hazards when performing service and/or maintenance of equipment.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections in this industry (NAICS 324110)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343615142.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.