OSHA Inspection: SKA BREWING CO.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SKA BREWING CO. in 225 GIRARD ST, DURANGO, CO 81303 (NAICS 312120). OSHA activity number 343616975.

Watch SKA Brewing CO. — free Get an email when a new federal OSHA severe-injury report for SKA Brewing CO. is published. One employer, no account, unsubscribe in one click.
Establishment
SKA BREWING CO.
Site address
225 GIRARD ST
City
DURANGO
State
CO
ZIP
81303
Mailing
225 GIRARD ST, DURANGO, CO 81303
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
312120
Employees
24
Ownership type
A

4 citations on file for this inspection.

1910.219 C04 I

Serious Gravity 1 5 instances 4 exposed
Issued
Abate by
Penalty
Initial $2619.00 · Current $1400.00 Reduced
29 CFR 1910.219(c)(4)(i): Unguarded shaft end(s) projected more than one half the diameter of the shaft:      (a) On or about November 15, 2018, and at times prior, the employer did not ensure that employees were protected from caught-in hazards while working next to unguarded end shafts that projected more than one half the diameter of the shaft. Employees were exposed to caught-in hazards in that at least 5 unguarded projecting shafts were observed in the Nigrelli Conveyor system located in the upper hall packaging area.      Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2619

1910.37 B02

Other-than-serious 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":  (a) On or about November 15, 2018, and at times prior, the employer did not ensure that each exit was marked by a sign reading "Exit". Employees in the Annex room were exposed to fire-related hazards in that the two emergency doors in the room were not marked by Exit signs.   Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G01 II

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(ii): Flexible cords and cables were used for a purpose not approved by paragraphs A thorough L of this section:   (a) On or about November 15, 2018, and at times prior, the employer used a flexible cord for a purpose not approved by paragraphs A through L of this section. Employees were exposed to contact with electrical hazards in that the employer used a flexible cord as a substitute for permanent wiring on a 220V blower motor mounted on a wall behind vessel TDV7.             Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 F06 I

Other-than-serious 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(f)(6)(i): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information required by 29 CFR 1910.1200(f)(1)(i) through 29 CFR 1910.1200(f)(1)(v):  (a) On or about November 15, 2018, and at times prior, the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information required by the hazard communication standard. Employees in the brew deck area were exposed to contact with chemical hazards in that a 5-gal container with a Sodium Hydroxide solution was not labeled. The Sodium Hydroxide solution is used for cleaning purposes and is a known corrosive agent.       Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343616975.