ELBRIDGE, NY —
OSHA Inspection: NORTHEASTERN ELECTRONICS CO., INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of NORTHEASTERN ELECTRONICS CO., INC in 102 STATE ROUTE 5 WEST, ELBRIDGE, NY 13060 (NAICS 334417). OSHA activity number 343617718.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NORTHEASTERN ELECTRONICS CO., INC
- Site address
- 102 STATE ROUTE 5 WEST
- City
- ELBRIDGE
- State
- NY
- ZIP
- 13060
- Mailing
- P.O. BOX 217, ELBRIDGE, NY 13060
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334417
- Employees
- 40
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.212 A01
- Issued
- Mar 12, 2019
- Abate by
- Jul 1, 2019
- Penalty
- Initial $6,630 · Current $4,309 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a. Employees operating AMP-O-LECTRIC crimping machines with the use of a foot peddle. The machines were not equipped with point of operation guarding and employee's hands are within one inch of the point of operation. b. Employees operating Molex ATP-301 Air Tape Press crimping machines with the use of a foot peddle. The machines were not equipped with point of operation guarding and employee's hands are within one to two inches of the point of operation. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $4309.4
- — Z (S) $6630
1910.303 B02
- Issued
- Mar 12, 2019
- Abate by
- Mar 20, 2019
- Penalty
- Initial $3,978 · Current $2,586 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a. In the production area, on or about 11/20/18; Metal duplex receptacles attached to flexible power cords and were being used a extension cords against their listing and labeling instructions. The receptacles were not mounted as required. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $2585.7
- — Z (S) $3978
1910.1025 H01
- Issued
- Mar 12, 2019
- Abate by
- Apr 1, 2019
- Penalty
- Initial $3,978 · Current $2,586 Reduced
General-duty citation text
29 CFR 1910.1025(h)(1): All surfaces were not maintained as free as practicable of accumulations of lead: a. In the production areas, on or about 11/20/18: Employees use leaded solder in the production of electronic connectors. The employer had not implemented a housekeeping program to maintain surfaces free form accumulations of dust. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $2585.7
- — Z (S) $3978
1910.1025 L01 I
- Issued
- Mar 12, 2019
- Abate by
- Mar 25, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1025(l)(1)(i): Employee(s) working in an area where there is potential exposure to airborne lead at any level were not informed of the content of Appendices A and B of 29 CFR 1910.1025: a. Within the production area, on or about 11/20/18: Employees working with leaded solder were not trained with regard to the contents of Appendices A and B. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1025 M01 III
- Issued
- Mar 12, 2019
- Abate by
- Mar 25, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1025(m)(1)(iii): The employer did not include lead in the hazard communication program established to comply with the hazard communication standard (1910.1200). a. Within the production area, on or about 11/20/18: The employer's hazard communication program did not address lead exposure as is required in the standard. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 E01
- Issued
- Mar 12, 2019
- Abate by
- Mar 25, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program which at included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): a. In the production area, on or about 11/20/18: The employer had not written or developed a hazard communication program to address the hazards associated with the chemicals used in the facility such as but not limited to 186 Soldering Flux, Flux-Off Rosin Liquid and 245 Lead Alloy Solder Wire. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H01
- Issued
- Mar 12, 2019
- Abate by
- Mar 25, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a. In the production area, on or about 11/20/18: Employees working with hazardous chemicals such as but not limited to leaded and unleaded solder and flux-off. Employees had not received training with regard to the chemicals used in the workplace. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Northeastern Electronics CO., INC
View Northeastern Electronics CO., INC's full OSHA safety record →
More inspections in this industry (NAICS 334417)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343617718.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.