Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: AGUSTIN MARTINEZ HERNANDEZ

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of AGUSTIN MARTINEZ HERNANDEZ in 11631 CULEBRA RD, SAN ANTONIO, TX 78253 (NAICS 238170). OSHA activity number 343621041.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Agustin Martinez Hernandez for free Get an email when a new federal OSHA severe-injury report for Agustin Martinez Hernandez is published. One employer, no account, unsubscribe in one click.
Site address
11631 CULEBRA RD
City
SAN ANTONIO
State
TX
ZIP
78253
Mailing
5515 SNOW FOX ST., SAN ANTONIO, TX 78242
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
1
Ownership type
Private (A)

2 citations on file for this inspection.

1926.451 G01 VII

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 4, 2018
Penalty
Initial $3,326 · Current $3,326
29 CFR 1926.451(g)(1)(vii): Each employee was not protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of 29 CFR 1910.451:  Pradera Subdivision, Unit 124: On or about November 27, 2018, an employee was exposed to a fall hazard while installing siding onto a residential home using a pump jack scaffold without guardrails.
Recent events (1)
  • · Z (S) $3326

1926.452 J02

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 4, 2018
Penalty
Initial $3,326 · Current $3,326
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary:  Pradera Subdivision, Unit 124:  On or about November 27, 2018, an employee was exposed to fall hazards while installing siding onto a residential building using a pump jack scaffold that was not secured at the top or bottom.
Recent events (1)
  • · Z (S) $3326

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343621041.