Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,991Inspections Most recent open 2026-08-24 Last loaded 2026-08-27

OSHA Inspection: CUSTOMS AND BORDER PROTECTION, BORDER PATROL TRAINING FACILITY

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of CUSTOMS AND BORDER PROTECTION, BORDER PATROL TRAINING FACILITY in 1427 SUNSET, FERNDALE, WA 98248 (NAICS 928110). OSHA activity number 343622890.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Customs and Border Protection, Border Patrol Training Facility for free Get an email when a new federal OSHA severe-injury report for Customs and Border Protection, Border Patrol Training Facility is published. One employer, no account, unsubscribe in one click.
Site address
1427 SUNSET
City
FERNDALE
State
WA
ZIP
98248
Mailing
1427 SUNSET, FERNDALE, WA 98248
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
928110
Employees
25
Ownership type
Federal government (D)

6 citations on file for this inspection.

1910.305 G01 IV A

Serious Gravity 1 1 instance 25 exposed
Issued
Apr 23, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used as a substitute for the fixed wiring of a structure:   a) Workout Area, where a red and black extension cord was plugged into a receptacle located approximately 15 feet from the gym equipment and used to supply power to two Vision Fitness treadmills and the Precor EFX 546 treadmill.
Recent events (1)
  • · Z (S) $0

1910.145 C02 I

Serious Gravity 1 1 instance 25 exposed
Issued
Apr 23, 2019
Abate by
Jun 10, 2019
Penalty
Initial $0 · Current $0

Hazardous substances 1591

29 CFR 1910.145(c)(2)(i): Caution signs were not used to warn against potential hazards or to caution against unsafe practices:   a) Gun Cleaning Area , where the employer did not post caution signs to alert employees of the presence of lead and the precautions to take while performing tasks associated with , but not limited to, gun cleaning.
Recent events (1)
  • · Z (S) $0

1910.303 B02

Serious Gravity 1 2 instances 25 exposed
Issued
Apr 23, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled equipment was not installed and used in accordance with any instructions included in the listing or labeling:   a) Facility, where electrical equipment not used as listed or labeled included:  1. Office, where the APC relocatable power tap was used to supply power to the Lasko floor heater.  2. Workout Area, where the Belkin relocatable power tap was daisy chained with a red and black extension cord and used to supply power to two Vision Fitness treadmills and the Precor EFX 546 treadmill.
Recent events (1)
  • · Z (S) $0

1910.157 E02

Other-than-serious 1 instance 25 exposed
Issued
Apr 23, 2019
Abate by
Jun 10, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:   a) Facility, where employees would be expected to fight incipient stage fires, the Amerex fire extinguishers were not inspected on a monthly basis.
Recent events (1)
  • · Z (O) $0

1910.303 G01 II

Other-than-serious 2 instances 25 exposed
Issued
Apr 23, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): Working space for equipment likely to require examination, adjustment, servicing, or maintenance while energized was used for storage:   a)  Warehouse, where items stored in front of electrical panels included:   1. SOD Area, items including a portable compressor, tires, a rim, and boxes of casings were stored in front of electrical panel C.  2. Canine Training Area, items including suitcases were stored in front of electrical panels CEL and CEH .
Recent events (1)
  • · Z (O) $0

1910.1200 G08

Other-than-serious 1 instance 25 exposed
Issued
Apr 23, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work shift to employees when they were in their work area(s):   a) Facility, where safety data sheets were not maintained for ammunition including, but not limited to, Federal Ammunition .40 S&W.
Recent events (1)
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343622890.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.